Commercial kitchen equipment, from a public bid set
A school kitchen, taken off its plan and spec.
The kitchen renovation at Hendersonville High School in Henderson County, North Carolina, from its public bid set: sheet AK-101 with its equipment schedule, and spec Sections 11 40 00 and 11 40 01. Every item is broken into the lines a kitchen equipment contractor bids: the equipment and its accessories, the custom stainless part by part, the walk-in assembly, and every gas, electrical, and plumbing connection with the trade that makes it.
The model is the plan in 3D, each piece at its plan location and its specified size. Pick a numbered point to fly to an area and read what the takeoff found there.
What came back
287 takeoff lines across 59 marks and 99 units: 6 gas connections (756K Btu/hr), 36 electrical connections (75.8 kW on the schedule), 26 water and waste connections, and 15 indirect wastes (11 to a floor sink, 3 to a floor drain, and 1 to a floor trough).
25 flags, each tied to its sheet or spec paragraph: a mark on the plan that exists nowhere else, marks misprinted in the schedule, a refrigerant typo, a fryer the spec calls 62 in. wide that the plan draws at 31 in., a floor trough both the kitchen contractor and the plumber are told to carry, and shelving with no spec item. Nothing is guessed silently.
What this is
Matchline builds a takeoff system like this for one kitchen equipment contractor or dealer, in that company's own quote format, and runs it for them. The estimator gets the takeoff, the flags, and the connection schedule for the other trades in minutes, then prices it from their own price file.
Flags for the estimator
| Mark | Kind | What the documents say |
|---|---|---|
| K26 | Conflict | K26: the spec says "Provide floor trough with drain plate" (11 40 00 K26.14), the plan says "FLOOR TROUGH BY PLUMBING". Carried once by KEC; ask the consultant which trade carries it so it is not bought twice or missed. |
| K43 | Conflict | K43: Section 11 40 00 itemizes it as "POT RACK" (Metro, HD Super Solid Shelving Series), Section 11 40 01 as "WALL-MOUNTED RACK SHELF" (custom). One product is carried (POT RACK); ask which is meant. |
| K29 | Conflict | K29 FRYER BATTERY WITH FILTER: the spec gives 62 x 30 in nominal, the plan draws about 32 x 29 in. Settle which is meant before pricing (the model follows the plan). |
| K47 | Conflict | K47 DUNNAGE RACK: the spec gives 48 x 24 in nominal, the plan draws about 36 x 20 in. Settle which is meant before pricing (the model follows the plan). |
| K6A | Document defect | K6A is tagged on the plan (1×) but is not in the equipment schedule or the spec. Ask the consultant what it is before pricing; not carried. |
| K24 | Document defect | Schedule: schedule prints K22 again on the K24 row (overprint); ignored |
| K31 | Document defect | Schedule: schedule prints mark K31 on the K32 line; the MIXER W/ STAND row above has no mark, so K31 is assigned to it by sequence. Verify with the designer. |
| K32 | Document defect | Schedule: mark K31 printed on this row belongs to the MIXER W/ STAND row above (assigned by sequence) |
| K51 | Document defect | 11 40 01 K51.2: refrigerant written "R40A"; read as R-404A. Confirm (R-404A is being phased down; many jurisdictions now need a lower-GWP refrigerant such as R-448A or R-449A). |
| K28 | Document defect | K28: the spec asks for "Water filtration system" twice (11 40 00 K28.8; 11 40 00 K28.14); carried once, 2. |
| K44-K45 | Missing | K44-K45 STORAGE SHELVING: no item in Section 11 40 00 or 11 40 01; product, options and accessories are unknown. 27 carried as "per schedule", price on request. |
| P1 | Code | P1 hand sinks are by plumbing. FDA Food Code 5-204.11 needs a hand sink in food prep, dishwashing and service areas; 2 tagged here. Confirm one serves the dish room and one the cooking line. |
| M1 | Coordination | M1 grease exhaust hood is by mechanical (Division 23), including its fire suppression system unless the mechanical spec says otherwise. Confirm who furnishes the wet-chemical system (UL 300) and the gas shutoff interlock for the appliances under it, and that the hood covers every appliance under it with the required overhang (IMC 507, NFPA 96). |
| M2 | Coordination | M2 grease exhaust hood is by mechanical (Division 23), including its fire suppression system unless the mechanical spec says otherwise. Confirm who furnishes the wet-chemical system (UL 300) and the gas shutoff interlock for the appliances under it, and that the hood covers every appliance under it with the required overhang (IMC 507, NFPA 96). |
| E1 | Coordination | E1 utility distribution system is by mechanical. Items K25 (pot filler) and the gas cooking line connect to it; confirm connection sizes and the quick-disconnect points it provides. |
| — | Coordination | Gas: 6 connections, 756K Btu/hr connected (schedule). The mechanical/plumbing engineer sizes the gas train; the KEC's quick-disconnect kits must match each appliance inlet. |
| — | Coordination | Indirect wastes: 15 (11 to a floor sink, 3 to a floor drain, 1 to a floor trough). Floor sinks and troughs are by plumbing (plan note 3, AK-102); the KEC's lines end above the receptor with an air gap. |
| K1 | Assumption | K1 SOILED DISHTABLE: the spec sizes it "as shown on the drawings"; the top is carried at 156 x 26 in measured on the plan. Confirm against the AK-201 detail before the shop drawing. |
| K6 | Assumption | K6 CLEAN DISHTABLE: the spec sizes it "as shown on the drawings"; the top is carried at 86 x 32 in measured on the plan. Confirm against the AK-201 detail before the shop drawing. |
| K20 | Assumption | K20 PASS-THRU HOT CABINET: 1 existing to be relocated. Field-verify condition, utilities and that it fits the new location before bid; repairs are not carried. |
| K22 | Assumption | K22 ICE MACHINE & BIN: 1 existing to be relocated. Field-verify condition, utilities and that it fits the new location before bid; repairs are not carried. |
| K31 | Assumption | K31 MIXER W/ STAND: 1 existing to be relocated. Field-verify condition, utilities and that it fits the new location before bid; repairs are not carried. |
| K46 | Assumption | K46 STORAGE SHELVING: 1 existing to be relocated. Field-verify condition, utilities and that it fits the new location before bid; repairs are not carried. |
| K51 | Assumption | K51 WALK-IN COOLER: panel area, refrigeration line length and light count are field-verified items (the plan gives the box, not the route to the roof); carried as lots until measured. |
| K52 | Assumption | K52 WALK-IN FREEZER: panel area, refrigeration line length and light count are field-verified items (the plan gives the box, not the route to the roof); carried as lots until measured. |
The takeoff, mark by mark
Quantities: counted off the plan or the documents, derived by a rule from counted values, as specified from the spec text, assumed where the documents leave it to standard practice (flagged). Prices are left to the contractor's own price file.
K1 SOILED DISHTABLE Custom fabricated 9 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 1 | Fabrication | SOILED DISHTABLE | Custom fabricated | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K1 | counted |
| 2 | Coordination | Coordination | Coordinate with Item K2 Spray Assembly, Item K3 Garbage Disposal and Item K4 Dishmachine (refer to specifications, Section 11 4000). | By others | 11 40 01 K1.6 | as specified | ||
| 3 | Fabrication | Top | 14 ga stainless, one piece, 156 x 26 in (measured on the plan), raised rolled edge | 1 | ea | KEC furnish + install | 11 40 01 K1; plan at scale | counted |
| 4 | Fabrication | Sink bowl | 14 ga stainless, coved corners, 24 x 24 x 7 in deep | 1 | ea | KEC furnish + install | 11 40 01 K1 | as specified |
| 5 | Fabrication | Basket drain / waste | one per bowl (type not stated; lever waste assumed) | 1 | ea | KEC furnish + install | 11 40 01 K1 | assumed |
| 6 | Fabrication | Backsplash | 8 in high plus 2 in return at 45 deg, 156 in long; endsplash to match | 1 | ea | KEC furnish + install | 11 40 01 K1 | as specified |
| 7 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (4 pairs over 156 in) | 8 | ea | KEC furnish + install | 11 40 01 K1 | assumed |
| 8 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 3 | ea | KEC furnish + install | 11 40 01 K1 | assumed |
| 9 | Fabrication | Wall clips (zee) | 14 ga stainless, at 36 in on center (11 40 01 general) | 6 | ea | KEC furnish + install | 11 40 01 K1 | derived |
K2 SPRAY ASSEMBLY T&S B-0133-B 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 10 | Equipment | SPRAY ASSEMBLY | T&S B-0133-B | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K2 | counted |
| 11 | Plumbing connection | Hot water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 12 | Plumbing connection | Cold water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
K3 GARBAGE DISPOSAL In-SinkErator SS-300. Paragraph revised, 5/22/20 6 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 13 | Equipment | GARBAGE DISPOSAL | In-SinkErator SS-300. Paragraph revised, 5/22/20 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K3 | counted |
| 14 | Coordination | Approved alternates | In-SinkErator; Salvajor | KEC furnish + install | K3 spec B | as specified | ||
| 15 | Coordination | Coordination | Coordinate installation with Item K1 Soiled Dishtable (refer to specifications Section 11 4001). | By others | 11 40 00 K3.9 | as specified | ||
| 16 | Electrical connection | GARBAGE DISPOSAL | 208 V 3 ph, 6.0 A, 3 HP, at 12" AFF; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
| 17 | Plumbing connection | Cold water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 18 | Plumbing connection | Direct waste 2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
K4 DISHMACHINE Champion 44 DR 11 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 19 | Equipment | DISHMACHINE | Champion 44 DR | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K4 | counted |
| 20 | Coordination | Approved alternates | Champion; Moyer Diebel; Meiko | KEC furnish + install | K4 spec B | as specified | ||
| 21 | Coordination | Coordination | Coordinate ductwork by others for connection of pant leg ductwork to vent cowls. | By others | 11 40 00 K4.19 | as specified | ||
| 22 | Accessory | Fill line package | line strainer, solenoid valve, vacuum breaker, temperature gauge | 1 | set | KEC furnish + install | 11 40 00 K4.20 | as specified |
| 23 | Accessory | Drain water tempering kit | cold water mixes the discharge to code temperature (140 F max to the drain, IPC/local) | 1 | ea | KEC furnish + install | 11 40 00 K4.21 | as specified |
| 24 | Accessory | Table limit switch | mounted on the clean dishtable, wired to the machine | 1 | ea | KEC furnish + install | 11 40 00 K4.22 | as specified |
| 25 | Coordination | Coordination | Coordinate with Item K5 Booster Heater. | By others | 11 40 00 K4.23 | as specified | ||
| 26 | Electrical connection | DISHMACHINE | 480 V 3 ph, 31.0 A, 2, 1/6, HP, at 60" AFF; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
| 27 | Plumbing connection | Hot water 3/4" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 28 | Plumbing connection | Cold water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 29 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
K5 BOOSTER HEATER Hatco, Model C-12 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 30 | Equipment | BOOSTER HEATER | Hatco, Model C-12 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K5 | counted |
| 31 | Coordination | Approved alternates | Hatco Corporation; A.O. Smith; Approved equal | KEC furnish + install | K5 spec B | as specified | ||
| 32 | Accessory | Undercounter mounting kit | shock absorber and slide brackets | 1 | set | KEC furnish + install | 11 40 00 K5.8 | as specified |
| 33 | Electrical connection | BOOSTER HEATER | 480 V 3 ph, 14.5 A, 12.0 kW, at 24" AFF; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
K6 CLEAN DISHTABLE Custom fabricated 7 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 34 | Fabrication | CLEAN DISHTABLE | Custom fabricated | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K6 | counted |
| 35 | Fabrication | Top | 14 ga stainless, one piece, 86 x 32 in (measured on the plan), raised rolled edge | 1 | ea | KEC furnish + install | 11 40 01 K6; plan at scale | counted |
| 36 | Fabrication | Backsplash | 8 in high plus 2 in return at 45 deg, 86 in long | 1 | ea | KEC furnish + install | 11 40 01 K6 | as specified |
| 37 | Fabrication | Undershelf | 16 ga stainless, partial length | 1 | ea | KEC furnish + install | 11 40 01 K6 | as specified |
| 38 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (3 pairs over 86 in) | 6 | ea | KEC furnish + install | 11 40 01 K6 | assumed |
| 39 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 3 | ea | KEC furnish + install | 11 40 01 K6 | assumed |
| 40 | Fabrication | Wall clips (zee) | 14 ga stainless, at 36 in on center (11 40 01 general) | 4 | ea | KEC furnish + install | 11 40 01 K6 | derived |
K7 POT SINK Custom fabricated 10 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 41 | Fabrication | POT SINK | Custom fabricated | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K7 | counted |
| 42 | Fabrication | Top | 14 ga stainless, one piece, 120 x 36 in, raised turn-down edge | 1 | ea | KEC furnish + install | 11 40 01 K7 | as specified |
| 43 | Fabrication | Sink bowl | 14 ga stainless, coved corners, 24 x 30 x 14 in deep | 3 | ea | KEC furnish + install | 11 40 01 K7 | as specified |
| 44 | Fabrication | Lever waste, 2 in, with overflow | one per bowl | 3 | ea | KEC furnish + install | 11 40 01 K7 | derived |
| 45 | Fabrication | Drainboard | 24 in long, 14 ga, pitched to sink, with braces | 2 | ea | KEC furnish + install | 11 40 01 K7 | as specified |
| 46 | Fabrication | Backsplash | 7 in high plus 2 in return at 45 deg, 120 in long | 1 | ea | KEC furnish + install | 11 40 01 K7 | as specified |
| 47 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (3 pairs over 120 in) | 6 | ea | KEC furnish + install | 11 40 01 K7 | assumed |
| 48 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 3 | ea | KEC furnish + install | 11 40 01 K7 | assumed |
| 49 | Fabrication | Wall clips (zee) | 14 ga stainless, at 36 in on center (11 40 01 general) | 5 | ea | KEC furnish + install | 11 40 01 K7 | derived |
| 50 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
K8 SINK HEATER Hatco, 3CS-9B 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 51 | Equipment | SINK HEATER | Hatco, 3CS-9B | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K8 | counted |
| 52 | Coordination | Approved alternates | Hatco Corporation; A.O. Smith | KEC furnish + install | K8 spec B | as specified | ||
| 53 | Coordination | Coordination | Coordinate with Item K7 Pot Sink (refer to specifications, Section 11 4001). | By others | 11 40 00 K8.5 | as specified | ||
| 54 | Electrical connection | SINK HEATER | 480 V 3 ph, 10.8 A, 9.0 kW, at 12" AFF; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
K9 POT SINK SPRAY ASSEMBLY T&S B-0133-ADF14-B 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 55 | Equipment | POT SINK SPRAY ASSEMBLY | T&S B-0133-ADF14-B | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K9 | counted |
| 56 | Coordination | Coordination | Coordinate with Item K7 Pot Sink (refer to specifications, Section 11 4001). | By others | 11 40 00 K9.9 | as specified | ||
| 57 | Plumbing connection | Hot water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 58 | Plumbing connection | Cold water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
K10 POT SINK FAUCET T&S, B-0290-14 with B-TEE-EZK Swivel Tee 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 59 | Equipment | POT SINK FAUCET | T&S, B-0290-14 with B-TEE-EZK Swivel Tee | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K10 | counted |
| 60 | Coordination | Coordination | Coordinate with Item K7 Pot Sink (refer to specifications, Section 11 4001). | By others | 11 40 00 K10.7 | as specified | ||
| 61 | Plumbing connection | Hot water 3/4" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 62 | Plumbing connection | Cold water 3/4" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
K11 CASHIER STATION LTI SpecLine 28-CSE (S) 2 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 63 | Fabrication | CASHIER STATION | LTI SpecLine 28-CSE (S) | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 01 K11 | counted |
| 64 | Accessory | Casters | 5 inch diameter caster set, line-up locks. | 2 | set | KEC furnish + install | 11 40 01 K11.7 | as specified |
K12 CASHIER STATION LTI SpecLine 36-CSE (S) 2 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 65 | Fabrication | CASHIER STATION | LTI SpecLine 36-CSE (S) | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K12 | counted |
| 66 | Accessory | Casters | 5 inch diameter caster set, line-up locks. | 1 | set | KEC furnish + install | 11 40 01 K12.7 | as specified |
K13 SOLID TOP COUNTER LTI SpecLine 36-ST-S (S) 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 67 | Fabrication | SOLID TOP COUNTER | LTI SpecLine 36-ST-S (S) | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 01 K13 | counted |
| 68 | Accessory | Food shield / overshelf | No food shield. | 2 | ea | KEC furnish + install | 11 40 01 K13.4 | as specified |
| 69 | Accessory | Casters | 5 inch diameter caster set, line-up locks | 2 | set | KEC furnish + install | 11 40 01 K13.5 | as specified |
K14 SOLID TOP COUNTER LTI SpecLine 36-ST-S (S) 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 70 | Fabrication | SOLID TOP COUNTER | LTI SpecLine 36-ST-S (S) | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K14 | counted |
| 71 | Accessory | Food shield / overshelf | No food shield. | 1 | ea | KEC furnish + install | 11 40 01 K14.4 | as specified |
| 72 | Accessory | Casters | 5 inch diameter caster set, line-up locks | 1 | set | KEC furnish + install | 11 40 01 K14.5 | as specified |
K15 AIR CURTAIN MERCHANDISER Turbo Air, TOM-40W(B) N 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 73 | Equipment | AIR CURTAIN MERCHANDISER | Turbo Air, TOM-40W(B) N | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 00 K15 | counted |
| 74 | Coordination | Approved alternates | Master-Bilt; True Food Service Equipment, Inc; Turbo Air | KEC furnish + install | K15 spec B | as specified | ||
| 75 | Electrical connection | AIR CURTAIN MERCHANDISER | 120 V 1 ph, 15.5 A, 2@3/4 HP, at 12" AFF; cord and plug, NEMA 5-20P (receptacle by Div 26) | 2 | conn | By others | AK-101 schedule electrical | counted |
K16 HOT/COLD FOOD COUNTER LTI SpecLine 66-ST-L (S) with DI-QSCHP-4 Drop-In 5 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 76 | Fabrication | HOT/COLD FOOD COUNTER | LTI SpecLine 66-ST-L (S) with DI-QSCHP-4 Drop-In | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K16 | counted |
| 77 | Accessory | Food shield / overshelf | Two-tier overshelf, single service food shield. | 1 | ea | KEC furnish + install | 11 40 01 K16.7 | as specified |
| 78 | Accessory | Casters | 5 inch diameter caster set, line-up locks. | 1 | set | KEC furnish + install | 11 40 01 K16.9 | as specified |
| 79 | Electrical connection | HOT/COLD FOOD COUNTER | 120/208 V 1 ph, 14.4 A, 0.5 kW, at 12" AFF; cord and plug, NEMA 6-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
| 80 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
K17 SOLID TOP COUNTER LTI SpecLine 60-ST-S (S) 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 81 | Fabrication | SOLID TOP COUNTER | LTI SpecLine 60-ST-S (S) | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K17 | counted |
| 82 | Accessory | Food shield / overshelf | No food shield. | 1 | ea | KEC furnish + install | 11 40 01 K17.4 | as specified |
| 83 | Accessory | Casters | 5 inch diameter caster set, line-up locks | 1 | set | KEC furnish + install | 11 40 01 K17.6 | as specified |
K18 HOT FOOD COUNTER LTI SpecLine EF4-CPA-66-S (S) 5 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 84 | Fabrication | HOT FOOD COUNTER | LTI SpecLine EF4-CPA-66-S (S) | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K18 | counted |
| 85 | Accessory | Food shield / overshelf | Two-tier overshelf, single service food shield. | 1 | ea | KEC furnish + install | 11 40 01 K18.6 | as specified |
| 86 | Accessory | Casters | 5 inch diameter caster set, line-up locks. | 1 | set | KEC furnish + install | 11 40 01 K18.8 | as specified |
| 87 | Electrical connection | HOT FOOD COUNTER | 208 V 1 ph, 9.6 A, 2.0 kW, at 12" AFF; cord and plug, NEMA 6-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
| 88 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
K19 TRAY/SILVERWARE DISPENSER LTI SpecLine 36-RTS (S) 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 89 | Fabrication | TRAY/SILVERWARE DISPENSER | LTI SpecLine 36-RTS (S) | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 01 K19 | counted |
K20 PASS-THRU HOT CABINET, NEW Traulsen G-24314P. Items K20 and K21 shall be by the same manufacturer, in the 5 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 90 | Equipment | PASS-THRU HOT CABINET, NEW | Traulsen G-24314P. Items K20 and K21 shall be by the same manufacturer, in the same series. | 1 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 00 K20 | counted |
| 91 | Relocation | PASS-THRU HOT CABINET, existing | disconnect, protect, move, set, level and reconnect; verify condition before bid | 1 | ea | KEC relocate (existing) | AK-101 schedule remark "ONE UNIT NEW, ONE EXISTING TO BE RELOCATED" | counted |
| 92 | Coordination | Approved alternates | Delfield; Traulsen; True Food Service Equipment, Inc | KEC furnish + install | K20 spec B | as specified | ||
| 93 | Accessory | Casters | Heavy duty casters, lockable. | 1 | set | KEC furnish + install | 11 40 00 K20.11 | as specified |
| 94 | Electrical connection | PASS-THRU HOT CABINET | 208 V 1 ph, 17.7 A, 3.0 kW, at 44" AFF; cord and plug, NEMA 6-20P (receptacle by Div 26) | 2 | conn | By others | AK-101 schedule electrical | counted |
K21 PASS-THRU REFRIGERATOR Traulsen G20054-0032. Items K21 and K22 shall be by the same manufacturer, in t 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 95 | Equipment | PASS-THRU REFRIGERATOR | Traulsen G20054-0032. Items K21 and K22 shall be by the same manufacturer, in the same series. | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K21 | counted |
| 96 | Coordination | Approved alternates | Delfield; Traulsen; True Food Service Equipment, Inc | KEC furnish + install | K21 spec B | as specified | ||
| 97 | Accessory | Casters | Heavy duty casters, lockable. | 1 | set | KEC furnish + install | 11 40 00 K21.12 | as specified |
| 98 | Electrical connection | PASS-THRU REFRIGERATOR | 120 V 1 ph, 7.4 A, 3.5 kW, 1/3 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
K22 ICE MACHINE & BIN, existing disconnect, protect, move, set, level and reconnect; verify condition before bid 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 99 | Relocation | ICE MACHINE & BIN, existing | disconnect, protect, move, set, level and reconnect; verify condition before bid | 1 | ea | KEC relocate (existing) | AK-101 schedule remark "EXISTING TO BE RELOCATED" | counted |
| 100 | Electrical connection | ICE MACHINE & BIN | 120 V 1 ph, 11.3 A, 5.6 kW, at 44" AFF; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
| 101 | Plumbing connection | Cold water 3/8" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 102 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
K23 PIZZA CONVEYOR OVEN TurboChef High h Conveyor 2620 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 103 | Equipment | PIZZA CONVEYOR OVEN | TurboChef High h Conveyor 2620 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K23 | counted |
| 104 | Accessory | Equipment stand | stainless steel equipment stand, sized to oven. | 1 | ea | KEC furnish + install | 11 40 00 K23.9 | as specified |
| 105 | Electrical connection | PIZZA CONVEYOR OVEN | 208 V 3 ph, 40.0 A, 14.4 kW; cord and plug, NEMA 15-50P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
K24 INDUCTION RANGE WITH STAND Vollrath HIMC 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 106 | Equipment | INDUCTION RANGE WITH STAND | Vollrath HIMC | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K24 | counted |
| 107 | Accessory | Equipment stand | stainless steel equipment stand, sized to range, with lockable casters. | 1 | ea | KEC furnish + install | 11 40 00 K24.8 | as specified |
| 108 | Electrical connection | INDUCTION RANGE W/ STAND | 208 V 1 ph, 24 A, 5.8 kW, at 12" AFF; cord and plug, NEMA 6-30P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
K25 POT FILLER T&S B-0167 6 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 109 | Equipment | POT FILLER | T&S B-0167 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K25 | counted |
| 110 | Coordination | Approved alternates | Chicago Faucet; Fisher; T&S Brass and Bronze Works | KEC furnish + install | K25 spec B | as specified | ||
| 111 | Coordination | Coordination | Coordinate mounting at Utility Distribution System, by others. | By others | 11 40 00 K25.6 | as specified | ||
| 112 | Plumbing connection | Hot water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 113 | Plumbing connection | Cold water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 114 | Plumbing connection | Indirect waste to floor drain | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FD" | counted |
K26 TILTING SKILLET Cleveland SGL-40-T1 7 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 115 | Equipment | TILTING SKILLET | Cleveland SGL-40-T1 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K26 | counted |
| 116 | Coordination | Approved alternates | Cleveland; Groen; Southbend | KEC furnish + install | K26 spec B | as specified | ||
| 117 | Gas connection | Gas quick-disconnect hose kit | 3/4" x 48 in, ANSI Z21.69/CSA 6.16 coated hose, quick-disconnect, full-port gas valve, restraining cable and anchor (movable appliance) | 1 | kit | KEC furnish + install | 11 40 00 K26.11 | derived |
| 118 | Accessory | Floor trough with drain plate | sized to equipment | 1 | ea | KEC furnish + install | 11 40 00 K26.14 | as specified |
| 119 | Electrical connection | TILTING SKILLET | 120 V 1 ph, 1.4 A, at 12" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
| 120 | Plumbing connection | Indirect waste to floor trough | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FT" | counted |
| 121 | Gas connection | Gas 3/4" | 200K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system | 1 | conn | By others | AK-101 schedule gas | counted |
K27 DOUBLE CONVECTION OVEN Blodgett DFG-200, Double 6 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 122 | Equipment | DOUBLE CONVECTION OVEN | Blodgett DFG-200, Double | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K27 | counted |
| 123 | Coordination | Approved alternates | Blodgett; Garland; Vulcan | KEC furnish + install | K27 spec B | as specified | ||
| 124 | Accessory | Oven racks | removable, adjustable | 10 | ea | KEC furnish + install | 11 40 00 K27.5 | derived |
| 125 | Gas connection | Gas quick-disconnect hose kit | 3/4" x 48 in, ANSI Z21.69/CSA 6.16 coated hose, quick-disconnect, full-port gas valve, restraining cable and anchor (movable appliance) | 2 | kit | KEC furnish + install | 11 40 00 K27.11 | derived |
| 126 | Electrical connection | DOUBLE CONVECTION OVEN | 120 V 1 ph, 2@6.0 A, 2@1/2 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 2 | conn | By others | AK-101 schedule electrical | counted |
| 127 | Gas connection | Gas 3/4" | 2 @ 60K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system | 2 | conn | By others | AK-101 schedule gas | counted |
K28 DOUBLE COMBI OVEN Rational Combi-Duo 62 and 102 12 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 128 | Equipment | DOUBLE COMBI OVEN | Rational Combi-Duo 62 and 102 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K28 | counted |
| 129 | Coordination | Approved alternates | Blodgett; Rational; Approved Equal | KEC furnish + install | K28 spec B | as specified | ||
| 130 | Accessory | Water filtration system | manufacturer’s recommended best-quality deliming, descaling water filter. / single cartridge water filtration system recommended by manufacturer for use with each unit, rated NSF Class1, STD 42. | 2 | ea | KEC furnish + install | 11 40 00 K28.8; 11 40 00 K28.14 | as specified |
| 131 | Gas connection | Gas quick-disconnect hose kit | 3/4" x 48 in, ANSI Z21.69/CSA 6.16 coated hose, quick-disconnect, full-port gas valve, restraining cable and anchor (movable appliance) | 2 | kit | KEC furnish + install | 11 40 00 K28.13 | derived |
| 132 | Plumbing connection | Water quick-disconnect hose | 3/4" cold water, braided hose with quick disconnect | 2 | ea | KEC furnish + install | 11 40 00 K28.13 | derived |
| 133 | Accessory | Equipment stand | mobile stand. | 1 | ea | KEC furnish + install | 11 40 00 K28.15 | as specified |
| 134 | Electrical connection | DOUBLE COMBI OVEN | 208 V 1 ph, 3.7 A, at 24" AFF; cord and plug, NEMA 6-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
| 135 | Plumbing connection | Cold water 3/4" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 136 | Gas connection | Gas 3/4" | 106K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system | 1 | conn | By others | AK-101 schedule gas | counted |
| 137 | Electrical connection | DOUBLE COMBI OVEN, second unit | 208 V 1 ph, 3.9 A, at 44" AFF; cord and plug, NEMA 6-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
| 138 | Plumbing connection | Cold water 3/4" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 139 | Gas connection | Gas 3/4" | 170K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system | 1 | conn | By others | AK-101 schedule gas | counted |
K29 FRYER BATTERY WITH FILTER Frymaster FPPH255 7 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 140 | Equipment | FRYER BATTERY WITH FILTER | Frymaster FPPH255 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K29 | counted |
| 141 | Coordination | Approved alternates | Frymaster H55 Series; Pitco, Solstice Supreme Series; Vulcan-Hart, PowerFry5 Series | KEC furnish + install | K29 spec B | as specified | ||
| 142 | Accessory | Fry baskets and covers | Provide one lid, one frypot cover, one heavy-gauge twin fry basket and one heavy- gauge full fry basket, with insulated handles per each frypot. | 2 | set (per frypot) | KEC furnish + install | 11 40 00 K29.3 | as specified |
| 143 | Accessory | Casters | Heavy-duty swivel casters, lockable. | 1 | set | KEC furnish + install | 11 40 00 K29.10 | as specified |
| 144 | Gas connection | Gas quick-disconnect hose kit | 1" x 48 in, ANSI Z21.69/CSA 6.16 coated hose, quick-disconnect, full-port gas valve, restraining cable and anchor (movable appliance) | 1 | kit | KEC furnish + install | 11 40 00 K29.13 | derived |
| 145 | Electrical connection | FRYER BATTERY W/ FILTER | 120 V 1 ph, 10.0 A, at 24" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
| 146 | Gas connection | Gas 1" | 2 @ 80K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system | 1 | conn | By others | AK-101 schedule gas | counted |
K30 PAN RACK Cres Cor, Model 207-UA-13A 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 147 | Equipment | PAN RACK | Cres Cor, Model 207-UA-13A | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 00 K30 | counted |
| 148 | Coordination | Approved alternates | Cres Cor Company; Metro; Servolift | KEC furnish + install | K30 spec B | as specified | ||
| 149 | Accessory | Casters | 5 inch diameter swivel casters, two with brakes. | 2 | set | KEC furnish + install | 11 40 00 K30.4 | as specified |
K31 MIXER W/ STAND, existing disconnect, protect, move, set, level and reconnect; verify condition before bid 2 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 150 | Relocation | MIXER W/ STAND, existing | disconnect, protect, move, set, level and reconnect; verify condition before bid | 1 | ea | KEC relocate (existing) | AK-101 schedule remark "EXISTING TO BE RELOCATED" | counted |
| 151 | Electrical connection | MIXER W/ STAND | 120 V 1 ph, 8.2 A, 1/2 HP, at 44" AFF; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
K32 VEGETABLE PREP SINK Custom fabricated 10 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 152 | Fabrication | VEGETABLE PREP SINK | Custom fabricated | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K32 | counted |
| 153 | Coordination | Coordination | Coordinate with Item K32A Spray Assembly (refer to specifications section 11 4000). | By others | 11 40 01 K32.10 | as specified | ||
| 154 | Fabrication | Top | 14 ga stainless, one piece, 20 x 5 in | 1 | ea | KEC furnish + install | 11 40 01 K32 | as specified |
| 155 | Fabrication | Backsplash | 4 in high plus 2 in return at 45 deg, 20 in long | 1 | ea | KEC furnish + install | 11 40 01 K32 | as specified |
| 156 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 20 in) | 4 | ea | KEC furnish + install | 11 40 01 K32 | assumed |
| 157 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 3 | ea | KEC furnish + install | 11 40 01 K32 | assumed |
| 158 | Fabrication | Wall clips (zee) | 14 ga stainless, at 36 in on center (11 40 01 general) | 2 | ea | KEC furnish + install | 11 40 01 K32 | derived |
| 159 | Plumbing connection | Hot water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 160 | Plumbing connection | Cold water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 161 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
K33 MEAT PREP SINK Custom fabricated 13 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 162 | Fabrication | MEAT PREP SINK | Custom fabricated | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K33 | counted |
| 163 | Coordination | Coordination | Coordinate with Item K33A Faucet (refer to specifications section 11 4000). | By others | 11 40 01 K33.10 | as specified | ||
| 164 | Fabrication | Top | 14 ga stainless, one piece, 20 x 5 in | 1 | ea | KEC furnish + install | 11 40 01 K33 | as specified |
| 165 | Fabrication | Sink bowl | 14 ga stainless, coved corners, 24 x 24 x 12 in deep | 1 | ea | KEC furnish + install | 11 40 01 K33 | as specified |
| 166 | Fabrication | Basket drain / waste | one per bowl (type not stated; lever waste assumed) | 1 | ea | KEC furnish + install | 11 40 01 K33 | assumed |
| 167 | Fabrication | Backsplash | 4 in high plus 2 in return at 45 deg, 20 in long | 1 | ea | KEC furnish + install | 11 40 01 K33 | as specified |
| 168 | Fabrication | Undershelf | 16 ga stainless, partial length | 1 | ea | KEC furnish + install | 11 40 01 K33 | as specified |
| 169 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 20 in) | 4 | ea | KEC furnish + install | 11 40 01 K33 | assumed |
| 170 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 3 | ea | KEC furnish + install | 11 40 01 K33 | assumed |
| 171 | Fabrication | Wall clips (zee) | 14 ga stainless, at 36 in on center (11 40 01 general) | 2 | ea | KEC furnish + install | 11 40 01 K33 | derived |
| 172 | Plumbing connection | Hot water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 173 | Plumbing connection | Cold water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 1 | conn | By others | AK-101 schedule plumbing | counted |
| 174 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
K34 MEAT SLICER Globe, Model SG13A. Paragraph revised, 5/22/20 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 175 | Equipment | MEAT SLICER | Globe, Model SG13A. Paragraph revised, 5/22/20 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K34 | counted |
| 176 | Coordination | Approved alternates | Berkel; Globe | KEC furnish + install | K34 spec B | as specified | ||
| 177 | Electrical connection | MEAT SLICER | 120 V 1 ph, 2.5 A, 1/2 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
K35 FOOD PROCESSOR Robot Coupe, Model R502 2 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 178 | Equipment | FOOD PROCESSOR | Robot Coupe, Model R502 | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K35 | counted |
| 179 | Electrical connection | FOOD PROCESSOR | 120 V 1 ph, 12.0 A, 2 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
K36 WASHDOWN/HOSE REEL T&S B-1480 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 180 | Equipment | WASHDOWN/HOSE REEL | T&S B-1480 | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 00 K36 | counted |
| 181 | Plumbing connection | Hot water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 2 | conn | By others | AK-101 schedule plumbing | counted |
| 182 | Plumbing connection | Cold water 1/2" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 2 | conn | By others | AK-101 schedule plumbing | counted |
| 183 | Plumbing connection | Indirect waste to floor drain | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 2 | conn | KEC furnish + install | AK-101 schedule I.W. "FD" | counted |
K37 MOBILE WORKTABLE Custom fabricated 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 184 | Fabrication | MOBILE WORKTABLE | Custom fabricated | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 01 K37 | counted |
| 185 | Accessory | Casters | Heavy-duty swivel casters, two with brakes. | 2 | set | KEC furnish + install | 11 40 01 K37.5 | as specified |
| 186 | Fabrication | Top | 14 ga stainless, one piece, 20 x 5 in | 2 | ea | KEC furnish + install | 11 40 01 K37 | as specified |
| 187 | Fabrication | Undershelf | 16 ga stainless | 2 | ea | KEC furnish + install | 11 40 01 K37 | as specified |
K38 WORKTABLE Custom fabricated 5 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 188 | Fabrication | WORKTABLE | Custom fabricated | 3 | ea | KEC furnish + install | AK-101 plan (3 tags); 11 40 01 K38 | counted |
| 189 | Fabrication | Top | 14 ga stainless, one piece, 60 x 24 in | 3 | ea | KEC furnish + install | 11 40 01 K38 | as specified |
| 190 | Fabrication | Undershelf | 16 ga stainless | 3 | ea | KEC furnish + install | 11 40 01 K38 | as specified |
| 191 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 60 in) | 12 | ea | KEC furnish + install | 11 40 01 K38 | assumed |
| 192 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 9 | ea | KEC furnish + install | 11 40 01 K38 | assumed |
K39 WORKTABLE Custom fabricated 5 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 193 | Fabrication | WORKTABLE | Custom fabricated | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K39 | counted |
| 194 | Fabrication | Top | 14 ga stainless, one piece, 36 x 24 in | 1 | ea | KEC furnish + install | 11 40 01 K39 | as specified |
| 195 | Fabrication | Undershelf | 16 ga stainless | 1 | ea | KEC furnish + install | 11 40 01 K39 | as specified |
| 196 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 36 in) | 4 | ea | KEC furnish + install | 11 40 01 K39 | assumed |
| 197 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 3 | ea | KEC furnish + install | 11 40 01 K39 | assumed |
K40 PREP TABLE Custom fabricated 7 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 198 | Fabrication | PREP TABLE | Custom fabricated | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 01 K40 | counted |
| 199 | Fabrication | Top | 14 ga stainless, one piece, 20 x 5 in | 2 | ea | KEC furnish + install | 11 40 01 K40 | as specified |
| 200 | Fabrication | Backsplash | 4 in high plus 2 in return at 45 deg, 20 in long | 2 | ea | KEC furnish + install | 11 40 01 K40 | as specified |
| 201 | Fabrication | Undershelf | 16 ga stainless | 2 | ea | KEC furnish + install | 11 40 01 K40 | as specified |
| 202 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 20 in) | 8 | ea | KEC furnish + install | 11 40 01 K40 | assumed |
| 203 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 6 | ea | KEC furnish + install | 11 40 01 K40 | assumed |
| 204 | Fabrication | Wall clips (zee) | 14 ga stainless, at 36 in on center (11 40 01 general) | 4 | ea | KEC furnish + install | 11 40 01 K40 | derived |
K41 PREP TABLE Custom fabricated 7 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 205 | Fabrication | PREP TABLE | Custom fabricated | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 01 K41 | counted |
| 206 | Fabrication | Top | 14 ga stainless, one piece, 20 x 5 in | 2 | ea | KEC furnish + install | 11 40 01 K41 | as specified |
| 207 | Fabrication | Backsplash | 4 in high plus 2 in return at 45 deg, 20 in long | 2 | ea | KEC furnish + install | 11 40 01 K41 | as specified |
| 208 | Fabrication | Undershelf | 16 ga stainless | 2 | ea | KEC furnish + install | 11 40 01 K41 | as specified |
| 209 | Fabrication | Legs | 16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 20 in) | 8 | ea | KEC furnish + install | 11 40 01 K41 | assumed |
| 210 | Fabrication | Crossrails | 16 ga stainless tube, 1-1/4 in OD, sides and back | 6 | ea | KEC furnish + install | 11 40 01 K41 | assumed |
| 211 | Fabrication | Wall clips (zee) | 14 ga stainless, at 36 in on center (11 40 01 general) | 4 | ea | KEC furnish + install | 11 40 01 K41 | derived |
K42 DRYING RACKS per schedule 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 212 | Equipment | DRYING RACKS | per schedule | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 00 K42 | counted |
| 213 | Coordination | Approved alternates | Eagle Group, Lifestor; Metro, Metromax 4 Series | KEC furnish + install | K42 spec B | as specified | ||
| 214 | Accessory | Tray drying racks | one at 3 in spacing and one at 1-1/2 in spacing per shelving unit | 4 | ea | KEC furnish + install | 11 40 00 K42.7 | derived |
| 215 | Accessory | Casters | Heavy-duty casters, two with brakes. | 2 | set | KEC furnish + install | 11 40 00 K42.9 | as specified |
K43 POT RACK Metro, HD Super Solid Shelving Series 3 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 216 | Fabrication | POT RACK | Metro, HD Super Solid Shelving Series | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 00 K43 | counted |
| 217 | Coordination | Approved alternates | Eagle Group, Lifestor; Metro, Metromax 4 Series | KEC furnish + install | K43 spec B | as specified | ||
| 218 | Accessory | Casters | Heavy-duty casters, two with brakes. ITEMS K44, K45: STORAGE SHELVING | 2 | set | KEC furnish + install | 11 40 00 K43.5 | as specified |
K44-K45 STORAGE SHELVING per schedule 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 219 | Equipment | STORAGE SHELVING | per schedule | 27 | ea | KEC furnish + install | AK-101 plan (27 tags); no spec item | counted |
K46 STORAGE SHELVING, existing disconnect, protect, move, set, level and reconnect; verify condition before bid 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 220 | Relocation | STORAGE SHELVING, existing | disconnect, protect, move, set, level and reconnect; verify condition before bid | 1 | ea | KEC relocate (existing) | AK-101 schedule remark "EXISTING RACK SYSTEM TO BE RELOCATED" | counted |
K47 DUNNAGE RACK Metro HP55TFC. Rack may be custom fabricated at contractor’s option. 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 221 | Equipment | DUNNAGE RACK | Metro HP55TFC. Rack may be custom fabricated at contractor’s option. | 3 | ea | KEC furnish + install | AK-101 plan (3 tags); 11 40 00 K47 | counted |
K48 UTILITY CART Lakeside, Models 953 and 954, Tough Transport Series. Cart may be custom fabric 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 222 | Equipment | UTILITY CART | Lakeside, Models 953 and 954, Tough Transport Series. Cart may be custom fabricated at contractor’s option. | 2 | ea | KEC furnish + install | AK-101 plan (2 tags); 11 40 00 K48 | counted |
K49 PIZZA MERCHANDISER Hatco GRPWS-4824T 2 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 223 | Equipment | PIZZA MERCHANDISER | Hatco GRPWS-4824T | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 00 K49 | counted |
| 224 | Electrical connection | PIZZA MERCHANDISER | 208 V 1 ph, 10.0 A, 3.6 kW; cord and plug, NEMA 6-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
K50 COLD FOOD COUNTER LTI SpecLine 60-CFMX-S (S) 5 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 225 | Fabrication | COLD FOOD COUNTER | LTI SpecLine 60-CFMX-S (S) | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K50 | counted |
| 226 | Accessory | Food shield / overshelf | Two tier glass overshelf with single-service food shield. | 1 | ea | KEC furnish + install | 11 40 01 K50.6 | as specified |
| 227 | Accessory | Casters | 5-inch diameter caster set, line-up locks. | 1 | set | KEC furnish + install | 11 40 01 K50.7 | as specified |
| 228 | Electrical connection | COLD FOOD COUNTER | 120 V 1 ph, 7.5 A, 1/3 HP; cord and plug, NEMA 5-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
| 229 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 1 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
K51 WALK-IN COOLER W.A. Brown 18 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 230 | Fabrication | WALK-IN COOLER | W.A. Brown | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K51 | counted |
| 231 | Walk-in | Insulated wall and ceiling panels | 4 in foamed-in-place polyurethane, 2.5 lb, 24 ga embossed galvanized both faces exposed, cam-lock; area from the plan (field verify) | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | assumed |
| 232 | Walk-in | Vinyl wall track | secures cooler walls to the quarry tile floor by others (no cooler floor) | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 233 | Walk-in | Door, 34 x 78 in | three lift-type hinges, 30 in 16 ga stainless kick plates both sides, sill wiper, padlocking pull handle with inside safety release, automatic closer | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 234 | Walk-in | Strip curtain | transparent vinyl, overlapping strips, aluminum hanging rod and brackets | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 235 | Walk-in | Diamond tread wainscot | 1/8 in, exposed front exterior, floor to 48 in AFF | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | assumed |
| 236 | Walk-in | Closure panels and top closure | trim to building surfaces; top closure with C-channel rails, lift-out sections 48 in max | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 237 | Walk-in | Utility sleeves and escutcheons | foam-filled after lines are installed, stainless escutcheons | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 238 | Walk-in | Threshold / ramp | for carts into the compartment | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 239 | Walk-in | Vapor-proof light fixtures | prewired to a switch with pilot light in the door section; add fixtures to reach 30 fc at 30 in | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | assumed |
| 240 | Walk-in | Digital thermometer | owner furnished, KEC installs | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 241 | Walk-in | Condensing unit, medium temp | 1 HP air-cooled remote, roof mounted, painted galvanized housing, crankcase heater, prewired disconnect; roof curb coordinated | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 242 | Walk-in | Unit cooler (evaporator), low silhouette | at the locations shown | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 243 | Walk-in | Refrigeration piping and specialties | suction and liquid lines with insulation, sight glass, vibration eliminator, filter-drier, suction filter, TXV, solenoid, thermostat, pump-down circuit; conduit between coil and condensing unit; route length is field verified (roof) | 1 | system | KEC furnish + install | 11 40 01 K51 & K52 | assumed |
| 244 | Walk-in | Evaporator drain line | to a floor receptor outside the box | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 245 | Electrical connection | CONDENSING UNIT | 208 V 3 ph, 9.5 A, 1 HP; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
| 246 | Electrical connection | LIGHTS & DOOR HEATER | 120 V 1 ph, 2.8 A; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
| 247 | Electrical connection | EVAPORATOR COIL | 120 V 1 ph, 3.6 A; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
K52 WALK-IN FREEZER W.A. Brown 19 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 248 | Fabrication | WALK-IN FREEZER | W.A. Brown | 1 | ea | KEC furnish + install | AK-101 plan (1 tag); 11 40 01 K52 | counted |
| 249 | Walk-in | Insulated wall and ceiling panels | 4 in foamed-in-place polyurethane, 2.5 lb, 24 ga embossed galvanized both faces exposed, cam-lock; area from the plan (field verify) | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | assumed |
| 250 | Walk-in | Insulated floor panels | 850 psf, one-piece where possible, staggered joints; 0.10 in diamond tread aluminum finish | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 251 | Walk-in | Door, 34 x 78 in | three lift-type hinges, 30 in 16 ga stainless kick plates both sides, sill wiper, padlocking pull handle with inside safety release, automatic closer | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 252 | Walk-in | Heated door frame | perimeter heat at the freezer door | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 253 | Walk-in | Strip curtain | transparent vinyl, overlapping strips, aluminum hanging rod and brackets | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 254 | Walk-in | Diamond tread wainscot | 1/8 in, exposed front exterior, floor to 48 in AFF | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | assumed |
| 255 | Walk-in | Closure panels and top closure | trim to building surfaces; top closure with C-channel rails, lift-out sections 48 in max | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 256 | Walk-in | Utility sleeves and escutcheons | foam-filled after lines are installed, stainless escutcheons | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 257 | Walk-in | Threshold / ramp | for carts into the compartment | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 258 | Walk-in | Vapor-proof light fixtures | prewired to a switch with pilot light in the door section; add fixtures to reach 30 fc at 30 in | 1 | lot | KEC furnish + install | 11 40 01 K51 & K52 | assumed |
| 259 | Walk-in | Digital thermometer | owner furnished, KEC installs | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 260 | Walk-in | Condensing unit, low temp | 3 HP air-cooled remote, roof mounted, painted galvanized housing, crankcase heater, prewired disconnect; roof curb coordinated | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 261 | Walk-in | Unit cooler (evaporator), low silhouette | timed electric defrost; at the locations shown | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 262 | Walk-in | Refrigeration piping and specialties | suction and liquid lines with insulation, sight glass, vibration eliminator, filter-drier, suction filter, TXV, solenoid, thermostat, pump-down circuit; conduit between coil and condensing unit; route length is field verified (roof) | 1 | system | KEC furnish + install | 11 40 01 K51 & K52 | assumed |
| 263 | Walk-in | Evaporator drain line | to a floor receptor outside the box; heater cable and premolded insulation | 1 | ea | KEC furnish + install | 11 40 01 K51 & K52 | as specified |
| 264 | Electrical connection | CONDENSING UNIT | 208 V 3 ph, 16.9 A, 3 HP; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
| 265 | Electrical connection | LIGHTS & DOOR HEATER | 120 V 1 ph, 2.8 A; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
| 266 | Electrical connection | EVAPORATOR COIL | 208 V 1 ph, 16.0 A; direct connection, disconnect and final connection by Div 26 | 1 | conn | By others | AK-101 schedule electrical | counted |
K60 REACH-IN REFRIGERATOR Traulsen G20010; (1) REQ'D, SEE SHEET A-752A FOR LOCATION 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 267 | Equipment | REACH-IN REFRIGERATOR | Traulsen G20010; (1) REQ'D, SEE SHEET A-752A FOR LOCATION | 1 | ea | KEC furnish + install | AK-101 schedule "(1) REQ'D"; 11 40 00 K60 | as specified |
| 268 | Coordination | Approved alternates | Delfield; Traulsen; True Food Service Equipment, Inc | KEC furnish + install | K60 spec B | as specified | ||
| 269 | Accessory | Casters | Heavy duty casters, lockable. | 1 | set | KEC furnish + install | 11 40 00 K60.12 | as specified |
| 270 | Electrical connection | REACH-IN REFRIGERATOR | 120 V 1 ph, 7.4 A, 3.5 kW, 1/3 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
K61 REACH-IN FREEZER Traulsen G22010; (1) REQ'D, SEE SHEET A-752A FOR LOCATION 4 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 271 | Equipment | REACH-IN FREEZER | Traulsen G22010; (1) REQ'D, SEE SHEET A-752A FOR LOCATION | 1 | ea | KEC furnish + install | AK-101 schedule "(1) REQ'D"; 11 40 00 K61 | as specified |
| 272 | Coordination | Approved alternates | Delfield; Traulsen; True Food Service Equipment, Inc | KEC furnish + install | K61 spec B | as specified | ||
| 273 | Accessory | Casters | Heavy duty casters, lockable. | 1 | set | KEC furnish + install | 11 40 00 K61.12 | as specified |
| 274 | Electrical connection | REACH-IN FREEZER | 120 V 1 ph, 11.2 A, 9.9 kW, 1/3 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 1 | conn | By others | AK-101 schedule electrical | counted |
K62 ICE MACHINE Manitowoc NEO 240; (3) REQ'D, PROVIDE WATER FILTER SYSTEM 8 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 275 | Equipment | ICE MACHINE | Manitowoc NEO 240; (3) REQ'D, PROVIDE WATER FILTER SYSTEM | 3 | ea | KEC furnish + install | AK-101 schedule "(3) REQ'D"; 11 40 00 K62 | as specified |
| 276 | Coordination | Approved alternates | Hoshizaki; Manitowoc; Approved Equal | KEC furnish + install | K62 spec B | as specified | ||
| 277 | Accessory | Ice scoop and holder | Provide scoop, internal scoop holder | 3 | ea | KEC furnish + install | 11 40 00 K62.10 | as specified |
| 278 | Plumbing connection | Flexible water supply hose | 3/8" | 3 | ea | KEC furnish + install | 11 40 00 K62.12 | as specified |
| 279 | Accessory | Water filtration system | single cartridge water filtration system recommended by manufacturer for use with the ice machine, rated NSF Class1, STD 42. | 3 | ea | KEC furnish + install | 11 40 00 K62.13 | as specified |
| 280 | Electrical connection | ICE MACHINE & BIN | 120 V 1 ph, 7.0 A, 1/3 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26) | 3 | conn | By others | AK-101 schedule electrical | counted |
| 281 | Plumbing connection | Cold water 3/8" | rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for | 3 | conn | By others | AK-101 schedule plumbing | counted |
| 282 | Plumbing connection | Indirect waste to floor sink | KEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note) | 3 | conn | KEC furnish + install | AK-101 schedule I.W. "FS" | counted |
P1 HAND SINK SEE PLUMBING DRAWINGS 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 283 | By others | HAND SINK | SEE PLUMBING DRAWINGS | 2 | ea | By others (in contract) | AK-101 schedule, "Equipment by others, in contract" | counted |
M1 GREASE EXHAUST HOOD SEE MECHANICAL DRAWINGS 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 284 | By others | GREASE EXHAUST HOOD | SEE MECHANICAL DRAWINGS | 1 | ea | By others (in contract) | AK-101 schedule, "Equipment by others, in contract" | counted |
M2 GREASE EXHAUST HOOD SEE MECHANICAL DRAWINGS 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 285 | By others | GREASE EXHAUST HOOD | SEE MECHANICAL DRAWINGS | 1 | ea | By others (in contract) | AK-101 schedule, "Equipment by others, in contract" | counted |
M3 FLY FAN SEE MECHANICAL DRAWINGS 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 286 | By others | FLY FAN | SEE MECHANICAL DRAWINGS | 1 | ea | By others (in contract) | AK-101 schedule, "Equipment by others, in contract" | counted |
E1 UTILITY DISTRIBUTION SYSTEM SEE MECHANICAL DRAWINGS 1 lines
| # | Group | Item | Detail | Qty | Unit | By | Source | Basis |
|---|---|---|---|---|---|---|---|---|
| 287 | By others | UTILITY DISTRIBUTION SYSTEM | SEE MECHANICAL DRAWINGS | 1 | ea | By others (in contract) | AK-101 schedule, "Equipment by others, in contract" | counted |