matchline.studio

Commercial kitchen equipment, from a public bid set

A school kitchen, taken off its plan and spec.

The kitchen renovation at Hendersonville High School in Henderson County, North Carolina, from its public bid set: sheet AK-101 with its equipment schedule, and spec Sections 11 40 00 and 11 40 01. Every item is broken into the lines a kitchen equipment contractor bids: the equipment and its accessories, the custom stainless part by part, the walk-in assembly, and every gas, electrical, and plumbing connection with the trade that makes it.

The model is the plan in 3D, each piece at its plan location and its specified size. Pick a numbered point to fly to an area and read what the takeoff found there.

What came back

287 takeoff lines across 59 marks and 99 units: 6 gas connections (756K Btu/hr), 36 electrical connections (75.8 kW on the schedule), 26 water and waste connections, and 15 indirect wastes (11 to a floor sink, 3 to a floor drain, and 1 to a floor trough).

25 flags, each tied to its sheet or spec paragraph: a mark on the plan that exists nowhere else, marks misprinted in the schedule, a refrigerant typo, a fryer the spec calls 62 in. wide that the plan draws at 31 in., a floor trough both the kitchen contractor and the plumber are told to carry, and shelving with no spec item. Nothing is guessed silently.

Sheet AK-101, Enlarged Kitchen Plan and Kitchen Equipment Schedule, Hendersonville High School campus renovations
The source: sheet AK-101, Enlarged Kitchen Plan and Kitchen Equipment Schedule, Hendersonville High School Campus Renovations, Construction Documents, from Henderson County's public bid posting. Open the drawings (PDF)

What this is

Matchline builds a takeoff system like this for one kitchen equipment contractor or dealer, in that company's own quote format, and runs it for them. The estimator gets the takeoff, the flags, and the connection schedule for the other trades in minutes, then prices it from their own price file.

Talk to us

Flags for the estimator

MarkKindWhat the documents say
K26ConflictK26: the spec says "Provide floor trough with drain plate" (11 40 00 K26.14), the plan says "FLOOR TROUGH BY PLUMBING". Carried once by KEC; ask the consultant which trade carries it so it is not bought twice or missed.
K43ConflictK43: Section 11 40 00 itemizes it as "POT RACK" (Metro, HD Super Solid Shelving Series), Section 11 40 01 as "WALL-MOUNTED RACK SHELF" (custom). One product is carried (POT RACK); ask which is meant.
K29ConflictK29 FRYER BATTERY WITH FILTER: the spec gives 62 x 30 in nominal, the plan draws about 32 x 29 in. Settle which is meant before pricing (the model follows the plan).
K47ConflictK47 DUNNAGE RACK: the spec gives 48 x 24 in nominal, the plan draws about 36 x 20 in. Settle which is meant before pricing (the model follows the plan).
K6ADocument defectK6A is tagged on the plan (1×) but is not in the equipment schedule or the spec. Ask the consultant what it is before pricing; not carried.
K24Document defectSchedule: schedule prints K22 again on the K24 row (overprint); ignored
K31Document defectSchedule: schedule prints mark K31 on the K32 line; the MIXER W/ STAND row above has no mark, so K31 is assigned to it by sequence. Verify with the designer.
K32Document defectSchedule: mark K31 printed on this row belongs to the MIXER W/ STAND row above (assigned by sequence)
K51Document defect11 40 01 K51.2: refrigerant written "R40A"; read as R-404A. Confirm (R-404A is being phased down; many jurisdictions now need a lower-GWP refrigerant such as R-448A or R-449A).
K28Document defectK28: the spec asks for "Water filtration system" twice (11 40 00 K28.8; 11 40 00 K28.14); carried once, 2.
K44-K45MissingK44-K45 STORAGE SHELVING: no item in Section 11 40 00 or 11 40 01; product, options and accessories are unknown. 27 carried as "per schedule", price on request.
P1CodeP1 hand sinks are by plumbing. FDA Food Code 5-204.11 needs a hand sink in food prep, dishwashing and service areas; 2 tagged here. Confirm one serves the dish room and one the cooking line.
M1CoordinationM1 grease exhaust hood is by mechanical (Division 23), including its fire suppression system unless the mechanical spec says otherwise. Confirm who furnishes the wet-chemical system (UL 300) and the gas shutoff interlock for the appliances under it, and that the hood covers every appliance under it with the required overhang (IMC 507, NFPA 96).
M2CoordinationM2 grease exhaust hood is by mechanical (Division 23), including its fire suppression system unless the mechanical spec says otherwise. Confirm who furnishes the wet-chemical system (UL 300) and the gas shutoff interlock for the appliances under it, and that the hood covers every appliance under it with the required overhang (IMC 507, NFPA 96).
E1CoordinationE1 utility distribution system is by mechanical. Items K25 (pot filler) and the gas cooking line connect to it; confirm connection sizes and the quick-disconnect points it provides.
—CoordinationGas: 6 connections, 756K Btu/hr connected (schedule). The mechanical/plumbing engineer sizes the gas train; the KEC's quick-disconnect kits must match each appliance inlet.
—CoordinationIndirect wastes: 15 (11 to a floor sink, 3 to a floor drain, 1 to a floor trough). Floor sinks and troughs are by plumbing (plan note 3, AK-102); the KEC's lines end above the receptor with an air gap.
K1AssumptionK1 SOILED DISHTABLE: the spec sizes it "as shown on the drawings"; the top is carried at 156 x 26 in measured on the plan. Confirm against the AK-201 detail before the shop drawing.
K6AssumptionK6 CLEAN DISHTABLE: the spec sizes it "as shown on the drawings"; the top is carried at 86 x 32 in measured on the plan. Confirm against the AK-201 detail before the shop drawing.
K20AssumptionK20 PASS-THRU HOT CABINET: 1 existing to be relocated. Field-verify condition, utilities and that it fits the new location before bid; repairs are not carried.
K22AssumptionK22 ICE MACHINE & BIN: 1 existing to be relocated. Field-verify condition, utilities and that it fits the new location before bid; repairs are not carried.
K31AssumptionK31 MIXER W/ STAND: 1 existing to be relocated. Field-verify condition, utilities and that it fits the new location before bid; repairs are not carried.
K46AssumptionK46 STORAGE SHELVING: 1 existing to be relocated. Field-verify condition, utilities and that it fits the new location before bid; repairs are not carried.
K51AssumptionK51 WALK-IN COOLER: panel area, refrigeration line length and light count are field-verified items (the plan gives the box, not the route to the roof); carried as lots until measured.
K52AssumptionK52 WALK-IN FREEZER: panel area, refrigeration line length and light count are field-verified items (the plan gives the box, not the route to the roof); carried as lots until measured.

The takeoff, mark by mark

Quantities: counted off the plan or the documents, derived by a rule from counted values, as specified from the spec text, assumed where the documents leave it to standard practice (flagged). Prices are left to the contractor's own price file.

K1 SOILED DISHTABLE Custom fabricated 9 lines
#GroupItemDetailQtyUnitBySourceBasis
1FabricationSOILED DISHTABLECustom fabricated1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K1counted
2CoordinationCoordinationCoordinate with Item K2 Spray Assembly, Item K3 Garbage Disposal and Item K4 Dishmachine (refer to specifications, Section 11 4000).By others11 40 01 K1.6as specified
3FabricationTop14 ga stainless, one piece, 156 x 26 in (measured on the plan), raised rolled edge1eaKEC furnish + install11 40 01 K1; plan at scalecounted
4FabricationSink bowl14 ga stainless, coved corners, 24 x 24 x 7 in deep1eaKEC furnish + install11 40 01 K1as specified
5FabricationBasket drain / wasteone per bowl (type not stated; lever waste assumed)1eaKEC furnish + install11 40 01 K1assumed
6FabricationBacksplash8 in high plus 2 in return at 45 deg, 156 in long; endsplash to match1eaKEC furnish + install11 40 01 K1as specified
7FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (4 pairs over 156 in)8eaKEC furnish + install11 40 01 K1assumed
8FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back3eaKEC furnish + install11 40 01 K1assumed
9FabricationWall clips (zee)14 ga stainless, at 36 in on center (11 40 01 general)6eaKEC furnish + install11 40 01 K1derived
K2 SPRAY ASSEMBLY T&S B-0133-B 3 lines
#GroupItemDetailQtyUnitBySourceBasis
10EquipmentSPRAY ASSEMBLYT&S B-0133-B1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K2counted
11Plumbing connectionHot water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
12Plumbing connectionCold water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
K3 GARBAGE DISPOSAL In-SinkErator SS-300. Paragraph revised, 5/22/20 6 lines
#GroupItemDetailQtyUnitBySourceBasis
13EquipmentGARBAGE DISPOSALIn-SinkErator SS-300. Paragraph revised, 5/22/201eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K3counted
14CoordinationApproved alternatesIn-SinkErator; SalvajorKEC furnish + installK3 spec Bas specified
15CoordinationCoordinationCoordinate installation with Item K1 Soiled Dishtable (refer to specifications Section 11 4001).By others11 40 00 K3.9as specified
16Electrical connectionGARBAGE DISPOSAL208 V 3 ph, 6.0 A, 3 HP, at 12" AFF; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
17Plumbing connectionCold water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
18Plumbing connectionDirect waste 2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
K4 DISHMACHINE Champion 44 DR 11 lines
#GroupItemDetailQtyUnitBySourceBasis
19EquipmentDISHMACHINEChampion 44 DR1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K4counted
20CoordinationApproved alternatesChampion; Moyer Diebel; MeikoKEC furnish + installK4 spec Bas specified
21CoordinationCoordinationCoordinate ductwork by others for connection of pant leg ductwork to vent cowls.By others11 40 00 K4.19as specified
22AccessoryFill line packageline strainer, solenoid valve, vacuum breaker, temperature gauge1setKEC furnish + install11 40 00 K4.20as specified
23AccessoryDrain water tempering kitcold water mixes the discharge to code temperature (140 F max to the drain, IPC/local)1eaKEC furnish + install11 40 00 K4.21as specified
24AccessoryTable limit switchmounted on the clean dishtable, wired to the machine1eaKEC furnish + install11 40 00 K4.22as specified
25CoordinationCoordinationCoordinate with Item K5 Booster Heater.By others11 40 00 K4.23as specified
26Electrical connectionDISHMACHINE480 V 3 ph, 31.0 A, 2, 1/6, HP, at 60" AFF; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
27Plumbing connectionHot water 3/4"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
28Plumbing connectionCold water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
29Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FS"counted
K5 BOOSTER HEATER Hatco, Model C-12 4 lines
#GroupItemDetailQtyUnitBySourceBasis
30EquipmentBOOSTER HEATERHatco, Model C-121eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K5counted
31CoordinationApproved alternatesHatco Corporation; A.O. Smith; Approved equalKEC furnish + installK5 spec Bas specified
32AccessoryUndercounter mounting kitshock absorber and slide brackets1setKEC furnish + install11 40 00 K5.8as specified
33Electrical connectionBOOSTER HEATER480 V 3 ph, 14.5 A, 12.0 kW, at 24" AFF; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
K6 CLEAN DISHTABLE Custom fabricated 7 lines
#GroupItemDetailQtyUnitBySourceBasis
34FabricationCLEAN DISHTABLECustom fabricated1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K6counted
35FabricationTop14 ga stainless, one piece, 86 x 32 in (measured on the plan), raised rolled edge1eaKEC furnish + install11 40 01 K6; plan at scalecounted
36FabricationBacksplash8 in high plus 2 in return at 45 deg, 86 in long1eaKEC furnish + install11 40 01 K6as specified
37FabricationUndershelf16 ga stainless, partial length1eaKEC furnish + install11 40 01 K6as specified
38FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (3 pairs over 86 in)6eaKEC furnish + install11 40 01 K6assumed
39FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back3eaKEC furnish + install11 40 01 K6assumed
40FabricationWall clips (zee)14 ga stainless, at 36 in on center (11 40 01 general)4eaKEC furnish + install11 40 01 K6derived
K7 POT SINK Custom fabricated 10 lines
#GroupItemDetailQtyUnitBySourceBasis
41FabricationPOT SINKCustom fabricated1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K7counted
42FabricationTop14 ga stainless, one piece, 120 x 36 in, raised turn-down edge1eaKEC furnish + install11 40 01 K7as specified
43FabricationSink bowl14 ga stainless, coved corners, 24 x 30 x 14 in deep3eaKEC furnish + install11 40 01 K7as specified
44FabricationLever waste, 2 in, with overflowone per bowl3eaKEC furnish + install11 40 01 K7derived
45FabricationDrainboard24 in long, 14 ga, pitched to sink, with braces2eaKEC furnish + install11 40 01 K7as specified
46FabricationBacksplash7 in high plus 2 in return at 45 deg, 120 in long1eaKEC furnish + install11 40 01 K7as specified
47FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (3 pairs over 120 in)6eaKEC furnish + install11 40 01 K7assumed
48FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back3eaKEC furnish + install11 40 01 K7assumed
49FabricationWall clips (zee)14 ga stainless, at 36 in on center (11 40 01 general)5eaKEC furnish + install11 40 01 K7derived
50Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FS"counted
K8 SINK HEATER Hatco, 3CS-9B 4 lines
#GroupItemDetailQtyUnitBySourceBasis
51EquipmentSINK HEATERHatco, 3CS-9B1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K8counted
52CoordinationApproved alternatesHatco Corporation; A.O. SmithKEC furnish + installK8 spec Bas specified
53CoordinationCoordinationCoordinate with Item K7 Pot Sink (refer to specifications, Section 11 4001).By others11 40 00 K8.5as specified
54Electrical connectionSINK HEATER480 V 3 ph, 10.8 A, 9.0 kW, at 12" AFF; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
K9 POT SINK SPRAY ASSEMBLY T&S B-0133-ADF14-B 4 lines
#GroupItemDetailQtyUnitBySourceBasis
55EquipmentPOT SINK SPRAY ASSEMBLYT&S B-0133-ADF14-B1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K9counted
56CoordinationCoordinationCoordinate with Item K7 Pot Sink (refer to specifications, Section 11 4001).By others11 40 00 K9.9as specified
57Plumbing connectionHot water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
58Plumbing connectionCold water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
K10 POT SINK FAUCET T&S, B-0290-14 with B-TEE-EZK Swivel Tee 4 lines
#GroupItemDetailQtyUnitBySourceBasis
59EquipmentPOT SINK FAUCETT&S, B-0290-14 with B-TEE-EZK Swivel Tee1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K10counted
60CoordinationCoordinationCoordinate with Item K7 Pot Sink (refer to specifications, Section 11 4001).By others11 40 00 K10.7as specified
61Plumbing connectionHot water 3/4"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
62Plumbing connectionCold water 3/4"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
K11 CASHIER STATION LTI SpecLine 28-CSE (S) 2 lines
#GroupItemDetailQtyUnitBySourceBasis
63FabricationCASHIER STATIONLTI SpecLine 28-CSE (S)2eaKEC furnish + installAK-101 plan (2 tags); 11 40 01 K11counted
64AccessoryCasters5 inch diameter caster set, line-up locks.2setKEC furnish + install11 40 01 K11.7as specified
K12 CASHIER STATION LTI SpecLine 36-CSE (S) 2 lines
#GroupItemDetailQtyUnitBySourceBasis
65FabricationCASHIER STATIONLTI SpecLine 36-CSE (S)1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K12counted
66AccessoryCasters5 inch diameter caster set, line-up locks.1setKEC furnish + install11 40 01 K12.7as specified
K13 SOLID TOP COUNTER LTI SpecLine 36-ST-S (S) 3 lines
#GroupItemDetailQtyUnitBySourceBasis
67FabricationSOLID TOP COUNTERLTI SpecLine 36-ST-S (S)2eaKEC furnish + installAK-101 plan (2 tags); 11 40 01 K13counted
68AccessoryFood shield / overshelfNo food shield.2eaKEC furnish + install11 40 01 K13.4as specified
69AccessoryCasters5 inch diameter caster set, line-up locks2setKEC furnish + install11 40 01 K13.5as specified
K14 SOLID TOP COUNTER LTI SpecLine 36-ST-S (S) 3 lines
#GroupItemDetailQtyUnitBySourceBasis
70FabricationSOLID TOP COUNTERLTI SpecLine 36-ST-S (S)1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K14counted
71AccessoryFood shield / overshelfNo food shield.1eaKEC furnish + install11 40 01 K14.4as specified
72AccessoryCasters5 inch diameter caster set, line-up locks1setKEC furnish + install11 40 01 K14.5as specified
K15 AIR CURTAIN MERCHANDISER Turbo Air, TOM-40W(B) N 3 lines
#GroupItemDetailQtyUnitBySourceBasis
73EquipmentAIR CURTAIN MERCHANDISERTurbo Air, TOM-40W(B) N2eaKEC furnish + installAK-101 plan (2 tags); 11 40 00 K15counted
74CoordinationApproved alternatesMaster-Bilt; True Food Service Equipment, Inc; Turbo AirKEC furnish + installK15 spec Bas specified
75Electrical connectionAIR CURTAIN MERCHANDISER120 V 1 ph, 15.5 A, 2@3/4 HP, at 12" AFF; cord and plug, NEMA 5-20P (receptacle by Div 26)2connBy othersAK-101 schedule electricalcounted
K16 HOT/COLD FOOD COUNTER LTI SpecLine 66-ST-L (S) with DI-QSCHP-4 Drop-In 5 lines
#GroupItemDetailQtyUnitBySourceBasis
76FabricationHOT/COLD FOOD COUNTERLTI SpecLine 66-ST-L (S) with DI-QSCHP-4 Drop-In1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K16counted
77AccessoryFood shield / overshelfTwo-tier overshelf, single service food shield.1eaKEC furnish + install11 40 01 K16.7as specified
78AccessoryCasters5 inch diameter caster set, line-up locks.1setKEC furnish + install11 40 01 K16.9as specified
79Electrical connectionHOT/COLD FOOD COUNTER120/208 V 1 ph, 14.4 A, 0.5 kW, at 12" AFF; cord and plug, NEMA 6-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
80Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FS"counted
K17 SOLID TOP COUNTER LTI SpecLine 60-ST-S (S) 3 lines
#GroupItemDetailQtyUnitBySourceBasis
81FabricationSOLID TOP COUNTERLTI SpecLine 60-ST-S (S)1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K17counted
82AccessoryFood shield / overshelfNo food shield.1eaKEC furnish + install11 40 01 K17.4as specified
83AccessoryCasters5 inch diameter caster set, line-up locks1setKEC furnish + install11 40 01 K17.6as specified
K18 HOT FOOD COUNTER LTI SpecLine EF4-CPA-66-S (S) 5 lines
#GroupItemDetailQtyUnitBySourceBasis
84FabricationHOT FOOD COUNTERLTI SpecLine EF4-CPA-66-S (S)1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K18counted
85AccessoryFood shield / overshelfTwo-tier overshelf, single service food shield.1eaKEC furnish + install11 40 01 K18.6as specified
86AccessoryCasters5 inch diameter caster set, line-up locks.1setKEC furnish + install11 40 01 K18.8as specified
87Electrical connectionHOT FOOD COUNTER208 V 1 ph, 9.6 A, 2.0 kW, at 12" AFF; cord and plug, NEMA 6-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
88Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FS"counted
K19 TRAY/SILVERWARE DISPENSER LTI SpecLine 36-RTS (S) 1 lines
#GroupItemDetailQtyUnitBySourceBasis
89FabricationTRAY/SILVERWARE DISPENSERLTI SpecLine 36-RTS (S)2eaKEC furnish + installAK-101 plan (2 tags); 11 40 01 K19counted
K20 PASS-THRU HOT CABINET, NEW Traulsen G-24314P. Items K20 and K21 shall be by the same manufacturer, in the 5 lines
#GroupItemDetailQtyUnitBySourceBasis
90EquipmentPASS-THRU HOT CABINET, NEWTraulsen G-24314P. Items K20 and K21 shall be by the same manufacturer, in the same series.1eaKEC furnish + installAK-101 plan (2 tags); 11 40 00 K20counted
91RelocationPASS-THRU HOT CABINET, existingdisconnect, protect, move, set, level and reconnect; verify condition before bid1eaKEC relocate (existing)AK-101 schedule remark "ONE UNIT NEW, ONE EXISTING TO BE RELOCATED"counted
92CoordinationApproved alternatesDelfield; Traulsen; True Food Service Equipment, IncKEC furnish + installK20 spec Bas specified
93AccessoryCastersHeavy duty casters, lockable.1setKEC furnish + install11 40 00 K20.11as specified
94Electrical connectionPASS-THRU HOT CABINET208 V 1 ph, 17.7 A, 3.0 kW, at 44" AFF; cord and plug, NEMA 6-20P (receptacle by Div 26)2connBy othersAK-101 schedule electricalcounted
K21 PASS-THRU REFRIGERATOR Traulsen G20054-0032. Items K21 and K22 shall be by the same manufacturer, in t 4 lines
#GroupItemDetailQtyUnitBySourceBasis
95EquipmentPASS-THRU REFRIGERATORTraulsen G20054-0032. Items K21 and K22 shall be by the same manufacturer, in the same series.1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K21counted
96CoordinationApproved alternatesDelfield; Traulsen; True Food Service Equipment, IncKEC furnish + installK21 spec Bas specified
97AccessoryCastersHeavy duty casters, lockable.1setKEC furnish + install11 40 00 K21.12as specified
98Electrical connectionPASS-THRU REFRIGERATOR120 V 1 ph, 7.4 A, 3.5 kW, 1/3 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
K22 ICE MACHINE & BIN, existing disconnect, protect, move, set, level and reconnect; verify condition before bid 4 lines
#GroupItemDetailQtyUnitBySourceBasis
99RelocationICE MACHINE & BIN, existingdisconnect, protect, move, set, level and reconnect; verify condition before bid1eaKEC relocate (existing)AK-101 schedule remark "EXISTING TO BE RELOCATED"counted
100Electrical connectionICE MACHINE & BIN120 V 1 ph, 11.3 A, 5.6 kW, at 44" AFF; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
101Plumbing connectionCold water 3/8"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
102Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FS"counted
K23 PIZZA CONVEYOR OVEN TurboChef High h Conveyor 2620 3 lines
#GroupItemDetailQtyUnitBySourceBasis
103EquipmentPIZZA CONVEYOR OVENTurboChef High h Conveyor 26201eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K23counted
104AccessoryEquipment standstainless steel equipment stand, sized to oven.1eaKEC furnish + install11 40 00 K23.9as specified
105Electrical connectionPIZZA CONVEYOR OVEN208 V 3 ph, 40.0 A, 14.4 kW; cord and plug, NEMA 15-50P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
K24 INDUCTION RANGE WITH STAND Vollrath HIMC 3 lines
#GroupItemDetailQtyUnitBySourceBasis
106EquipmentINDUCTION RANGE WITH STANDVollrath HIMC1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K24counted
107AccessoryEquipment standstainless steel equipment stand, sized to range, with lockable casters.1eaKEC furnish + install11 40 00 K24.8as specified
108Electrical connectionINDUCTION RANGE W/ STAND208 V 1 ph, 24 A, 5.8 kW, at 12" AFF; cord and plug, NEMA 6-30P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
K25 POT FILLER T&S B-0167 6 lines
#GroupItemDetailQtyUnitBySourceBasis
109EquipmentPOT FILLERT&S B-01671eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K25counted
110CoordinationApproved alternatesChicago Faucet; Fisher; T&S Brass and Bronze WorksKEC furnish + installK25 spec Bas specified
111CoordinationCoordinationCoordinate mounting at Utility Distribution System, by others.By others11 40 00 K25.6as specified
112Plumbing connectionHot water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
113Plumbing connectionCold water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
114Plumbing connectionIndirect waste to floor drainKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FD"counted
K26 TILTING SKILLET Cleveland SGL-40-T1 7 lines
#GroupItemDetailQtyUnitBySourceBasis
115EquipmentTILTING SKILLETCleveland SGL-40-T11eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K26counted
116CoordinationApproved alternatesCleveland; Groen; SouthbendKEC furnish + installK26 spec Bas specified
117Gas connectionGas quick-disconnect hose kit3/4" x 48 in, ANSI Z21.69/CSA 6.16 coated hose, quick-disconnect, full-port gas valve, restraining cable and anchor (movable appliance)1kitKEC furnish + install11 40 00 K26.11derived
118AccessoryFloor trough with drain platesized to equipment1eaKEC furnish + install11 40 00 K26.14as specified
119Electrical connectionTILTING SKILLET120 V 1 ph, 1.4 A, at 12" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
120Plumbing connectionIndirect waste to floor troughKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FT"counted
121Gas connectionGas 3/4"200K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system1connBy othersAK-101 schedule gascounted
K27 DOUBLE CONVECTION OVEN Blodgett DFG-200, Double 6 lines
#GroupItemDetailQtyUnitBySourceBasis
122EquipmentDOUBLE CONVECTION OVENBlodgett DFG-200, Double1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K27counted
123CoordinationApproved alternatesBlodgett; Garland; VulcanKEC furnish + installK27 spec Bas specified
124AccessoryOven racksremovable, adjustable10eaKEC furnish + install11 40 00 K27.5derived
125Gas connectionGas quick-disconnect hose kit3/4" x 48 in, ANSI Z21.69/CSA 6.16 coated hose, quick-disconnect, full-port gas valve, restraining cable and anchor (movable appliance)2kitKEC furnish + install11 40 00 K27.11derived
126Electrical connectionDOUBLE CONVECTION OVEN120 V 1 ph, 2@6.0 A, 2@1/2 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)2connBy othersAK-101 schedule electricalcounted
127Gas connectionGas 3/4"2 @ 60K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system2connBy othersAK-101 schedule gascounted
K28 DOUBLE COMBI OVEN Rational Combi-Duo 62 and 102 12 lines
#GroupItemDetailQtyUnitBySourceBasis
128EquipmentDOUBLE COMBI OVENRational Combi-Duo 62 and 1021eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K28counted
129CoordinationApproved alternatesBlodgett; Rational; Approved EqualKEC furnish + installK28 spec Bas specified
130AccessoryWater filtration systemmanufacturer’s recommended best-quality deliming, descaling water filter. / single cartridge water filtration system recommended by manufacturer for use with each unit, rated NSF Class1, STD 42.2eaKEC furnish + install11 40 00 K28.8; 11 40 00 K28.14as specified
131Gas connectionGas quick-disconnect hose kit3/4" x 48 in, ANSI Z21.69/CSA 6.16 coated hose, quick-disconnect, full-port gas valve, restraining cable and anchor (movable appliance)2kitKEC furnish + install11 40 00 K28.13derived
132Plumbing connectionWater quick-disconnect hose3/4" cold water, braided hose with quick disconnect2eaKEC furnish + install11 40 00 K28.13derived
133AccessoryEquipment standmobile stand.1eaKEC furnish + install11 40 00 K28.15as specified
134Electrical connectionDOUBLE COMBI OVEN208 V 1 ph, 3.7 A, at 24" AFF; cord and plug, NEMA 6-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
135Plumbing connectionCold water 3/4"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
136Gas connectionGas 3/4"106K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system1connBy othersAK-101 schedule gascounted
137Electrical connectionDOUBLE COMBI OVEN, second unit208 V 1 ph, 3.9 A, at 44" AFF; cord and plug, NEMA 6-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
138Plumbing connectionCold water 3/4"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
139Gas connectionGas 3/4"170K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system1connBy othersAK-101 schedule gascounted
K29 FRYER BATTERY WITH FILTER Frymaster FPPH255 7 lines
#GroupItemDetailQtyUnitBySourceBasis
140EquipmentFRYER BATTERY WITH FILTERFrymaster FPPH2551eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K29counted
141CoordinationApproved alternatesFrymaster H55 Series; Pitco, Solstice Supreme Series; Vulcan-Hart, PowerFry5 SeriesKEC furnish + installK29 spec Bas specified
142AccessoryFry baskets and coversProvide one lid, one frypot cover, one heavy-gauge twin fry basket and one heavy- gauge full fry basket, with insulated handles per each frypot.2set (per frypot)KEC furnish + install11 40 00 K29.3as specified
143AccessoryCastersHeavy-duty swivel casters, lockable.1setKEC furnish + install11 40 00 K29.10as specified
144Gas connectionGas quick-disconnect hose kit1" x 48 in, ANSI Z21.69/CSA 6.16 coated hose, quick-disconnect, full-port gas valve, restraining cable and anchor (movable appliance)1kitKEC furnish + install11 40 00 K29.13derived
145Electrical connectionFRYER BATTERY W/ FILTER120 V 1 ph, 10.0 A, at 24" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
146Gas connectionGas 1"2 @ 80K Btu/hr; rough-in, shutoff and final connection by Div 22/23 at the utility distribution system1connBy othersAK-101 schedule gascounted
K30 PAN RACK Cres Cor, Model 207-UA-13A 3 lines
#GroupItemDetailQtyUnitBySourceBasis
147EquipmentPAN RACKCres Cor, Model 207-UA-13A2eaKEC furnish + installAK-101 plan (2 tags); 11 40 00 K30counted
148CoordinationApproved alternatesCres Cor Company; Metro; ServoliftKEC furnish + installK30 spec Bas specified
149AccessoryCasters5 inch diameter swivel casters, two with brakes.2setKEC furnish + install11 40 00 K30.4as specified
K31 MIXER W/ STAND, existing disconnect, protect, move, set, level and reconnect; verify condition before bid 2 lines
#GroupItemDetailQtyUnitBySourceBasis
150RelocationMIXER W/ STAND, existingdisconnect, protect, move, set, level and reconnect; verify condition before bid1eaKEC relocate (existing)AK-101 schedule remark "EXISTING TO BE RELOCATED"counted
151Electrical connectionMIXER W/ STAND120 V 1 ph, 8.2 A, 1/2 HP, at 44" AFF; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
K32 VEGETABLE PREP SINK Custom fabricated 10 lines
#GroupItemDetailQtyUnitBySourceBasis
152FabricationVEGETABLE PREP SINKCustom fabricated1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K32counted
153CoordinationCoordinationCoordinate with Item K32A Spray Assembly (refer to specifications section 11 4000).By others11 40 01 K32.10as specified
154FabricationTop14 ga stainless, one piece, 20 x 5 in1eaKEC furnish + install11 40 01 K32as specified
155FabricationBacksplash4 in high plus 2 in return at 45 deg, 20 in long1eaKEC furnish + install11 40 01 K32as specified
156FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 20 in)4eaKEC furnish + install11 40 01 K32assumed
157FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back3eaKEC furnish + install11 40 01 K32assumed
158FabricationWall clips (zee)14 ga stainless, at 36 in on center (11 40 01 general)2eaKEC furnish + install11 40 01 K32derived
159Plumbing connectionHot water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
160Plumbing connectionCold water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
161Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FS"counted
K33 MEAT PREP SINK Custom fabricated 13 lines
#GroupItemDetailQtyUnitBySourceBasis
162FabricationMEAT PREP SINKCustom fabricated1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K33counted
163CoordinationCoordinationCoordinate with Item K33A Faucet (refer to specifications section 11 4000).By others11 40 01 K33.10as specified
164FabricationTop14 ga stainless, one piece, 20 x 5 in1eaKEC furnish + install11 40 01 K33as specified
165FabricationSink bowl14 ga stainless, coved corners, 24 x 24 x 12 in deep1eaKEC furnish + install11 40 01 K33as specified
166FabricationBasket drain / wasteone per bowl (type not stated; lever waste assumed)1eaKEC furnish + install11 40 01 K33assumed
167FabricationBacksplash4 in high plus 2 in return at 45 deg, 20 in long1eaKEC furnish + install11 40 01 K33as specified
168FabricationUndershelf16 ga stainless, partial length1eaKEC furnish + install11 40 01 K33as specified
169FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 20 in)4eaKEC furnish + install11 40 01 K33assumed
170FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back3eaKEC furnish + install11 40 01 K33assumed
171FabricationWall clips (zee)14 ga stainless, at 36 in on center (11 40 01 general)2eaKEC furnish + install11 40 01 K33derived
172Plumbing connectionHot water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
173Plumbing connectionCold water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for1connBy othersAK-101 schedule plumbingcounted
174Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FS"counted
K34 MEAT SLICER Globe, Model SG13A. Paragraph revised, 5/22/20 3 lines
#GroupItemDetailQtyUnitBySourceBasis
175EquipmentMEAT SLICERGlobe, Model SG13A. Paragraph revised, 5/22/201eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K34counted
176CoordinationApproved alternatesBerkel; GlobeKEC furnish + installK34 spec Bas specified
177Electrical connectionMEAT SLICER120 V 1 ph, 2.5 A, 1/2 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
K35 FOOD PROCESSOR Robot Coupe, Model R502 2 lines
#GroupItemDetailQtyUnitBySourceBasis
178EquipmentFOOD PROCESSORRobot Coupe, Model R5021eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K35counted
179Electrical connectionFOOD PROCESSOR120 V 1 ph, 12.0 A, 2 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
K36 WASHDOWN/HOSE REEL T&S B-1480 4 lines
#GroupItemDetailQtyUnitBySourceBasis
180EquipmentWASHDOWN/HOSE REELT&S B-14802eaKEC furnish + installAK-101 plan (2 tags); 11 40 00 K36counted
181Plumbing connectionHot water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for2connBy othersAK-101 schedule plumbingcounted
182Plumbing connectionCold water 1/2"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for2connBy othersAK-101 schedule plumbingcounted
183Plumbing connectionIndirect waste to floor drainKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)2connKEC furnish + installAK-101 schedule I.W. "FD"counted
K37 MOBILE WORKTABLE Custom fabricated 4 lines
#GroupItemDetailQtyUnitBySourceBasis
184FabricationMOBILE WORKTABLECustom fabricated2eaKEC furnish + installAK-101 plan (2 tags); 11 40 01 K37counted
185AccessoryCastersHeavy-duty swivel casters, two with brakes.2setKEC furnish + install11 40 01 K37.5as specified
186FabricationTop14 ga stainless, one piece, 20 x 5 in2eaKEC furnish + install11 40 01 K37as specified
187FabricationUndershelf16 ga stainless2eaKEC furnish + install11 40 01 K37as specified
K38 WORKTABLE Custom fabricated 5 lines
#GroupItemDetailQtyUnitBySourceBasis
188FabricationWORKTABLECustom fabricated3eaKEC furnish + installAK-101 plan (3 tags); 11 40 01 K38counted
189FabricationTop14 ga stainless, one piece, 60 x 24 in3eaKEC furnish + install11 40 01 K38as specified
190FabricationUndershelf16 ga stainless3eaKEC furnish + install11 40 01 K38as specified
191FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 60 in)12eaKEC furnish + install11 40 01 K38assumed
192FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back9eaKEC furnish + install11 40 01 K38assumed
K39 WORKTABLE Custom fabricated 5 lines
#GroupItemDetailQtyUnitBySourceBasis
193FabricationWORKTABLECustom fabricated1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K39counted
194FabricationTop14 ga stainless, one piece, 36 x 24 in1eaKEC furnish + install11 40 01 K39as specified
195FabricationUndershelf16 ga stainless1eaKEC furnish + install11 40 01 K39as specified
196FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 36 in)4eaKEC furnish + install11 40 01 K39assumed
197FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back3eaKEC furnish + install11 40 01 K39assumed
K40 PREP TABLE Custom fabricated 7 lines
#GroupItemDetailQtyUnitBySourceBasis
198FabricationPREP TABLECustom fabricated2eaKEC furnish + installAK-101 plan (2 tags); 11 40 01 K40counted
199FabricationTop14 ga stainless, one piece, 20 x 5 in2eaKEC furnish + install11 40 01 K40as specified
200FabricationBacksplash4 in high plus 2 in return at 45 deg, 20 in long2eaKEC furnish + install11 40 01 K40as specified
201FabricationUndershelf16 ga stainless2eaKEC furnish + install11 40 01 K40as specified
202FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 20 in)8eaKEC furnish + install11 40 01 K40assumed
203FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back6eaKEC furnish + install11 40 01 K40assumed
204FabricationWall clips (zee)14 ga stainless, at 36 in on center (11 40 01 general)4eaKEC furnish + install11 40 01 K40derived
K41 PREP TABLE Custom fabricated 7 lines
#GroupItemDetailQtyUnitBySourceBasis
205FabricationPREP TABLECustom fabricated2eaKEC furnish + installAK-101 plan (2 tags); 11 40 01 K41counted
206FabricationTop14 ga stainless, one piece, 20 x 5 in2eaKEC furnish + install11 40 01 K41as specified
207FabricationBacksplash4 in high plus 2 in return at 45 deg, 20 in long2eaKEC furnish + install11 40 01 K41as specified
208FabricationUndershelf16 ga stainless2eaKEC furnish + install11 40 01 K41as specified
209FabricationLegs16 ga stainless tube, 1-5/8 in OD, closed gussets, adjustable bullet feet (2 pairs over 20 in)8eaKEC furnish + install11 40 01 K41assumed
210FabricationCrossrails16 ga stainless tube, 1-1/4 in OD, sides and back6eaKEC furnish + install11 40 01 K41assumed
211FabricationWall clips (zee)14 ga stainless, at 36 in on center (11 40 01 general)4eaKEC furnish + install11 40 01 K41derived
K42 DRYING RACKS per schedule 4 lines
#GroupItemDetailQtyUnitBySourceBasis
212EquipmentDRYING RACKSper schedule2eaKEC furnish + installAK-101 plan (2 tags); 11 40 00 K42counted
213CoordinationApproved alternatesEagle Group, Lifestor; Metro, Metromax 4 SeriesKEC furnish + installK42 spec Bas specified
214AccessoryTray drying racksone at 3 in spacing and one at 1-1/2 in spacing per shelving unit4eaKEC furnish + install11 40 00 K42.7derived
215AccessoryCastersHeavy-duty casters, two with brakes.2setKEC furnish + install11 40 00 K42.9as specified
K43 POT RACK Metro, HD Super Solid Shelving Series 3 lines
#GroupItemDetailQtyUnitBySourceBasis
216FabricationPOT RACKMetro, HD Super Solid Shelving Series2eaKEC furnish + installAK-101 plan (2 tags); 11 40 00 K43counted
217CoordinationApproved alternatesEagle Group, Lifestor; Metro, Metromax 4 SeriesKEC furnish + installK43 spec Bas specified
218AccessoryCastersHeavy-duty casters, two with brakes. ITEMS K44, K45: STORAGE SHELVING2setKEC furnish + install11 40 00 K43.5as specified
K44-K45 STORAGE SHELVING per schedule 1 lines
#GroupItemDetailQtyUnitBySourceBasis
219EquipmentSTORAGE SHELVINGper schedule27eaKEC furnish + installAK-101 plan (27 tags); no spec itemcounted
K46 STORAGE SHELVING, existing disconnect, protect, move, set, level and reconnect; verify condition before bid 1 lines
#GroupItemDetailQtyUnitBySourceBasis
220RelocationSTORAGE SHELVING, existingdisconnect, protect, move, set, level and reconnect; verify condition before bid1eaKEC relocate (existing)AK-101 schedule remark "EXISTING RACK SYSTEM TO BE RELOCATED"counted
K47 DUNNAGE RACK Metro HP55TFC. Rack may be custom fabricated at contractor’s option. 1 lines
#GroupItemDetailQtyUnitBySourceBasis
221EquipmentDUNNAGE RACKMetro HP55TFC. Rack may be custom fabricated at contractor’s option.3eaKEC furnish + installAK-101 plan (3 tags); 11 40 00 K47counted
K48 UTILITY CART Lakeside, Models 953 and 954, Tough Transport Series. Cart may be custom fabric 1 lines
#GroupItemDetailQtyUnitBySourceBasis
222EquipmentUTILITY CARTLakeside, Models 953 and 954, Tough Transport Series. Cart may be custom fabricated at contractor’s option.2eaKEC furnish + installAK-101 plan (2 tags); 11 40 00 K48counted
K49 PIZZA MERCHANDISER Hatco GRPWS-4824T 2 lines
#GroupItemDetailQtyUnitBySourceBasis
223EquipmentPIZZA MERCHANDISERHatco GRPWS-4824T1eaKEC furnish + installAK-101 plan (1 tag); 11 40 00 K49counted
224Electrical connectionPIZZA MERCHANDISER208 V 1 ph, 10.0 A, 3.6 kW; cord and plug, NEMA 6-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
K50 COLD FOOD COUNTER LTI SpecLine 60-CFMX-S (S) 5 lines
#GroupItemDetailQtyUnitBySourceBasis
225FabricationCOLD FOOD COUNTERLTI SpecLine 60-CFMX-S (S)1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K50counted
226AccessoryFood shield / overshelfTwo tier glass overshelf with single-service food shield.1eaKEC furnish + install11 40 01 K50.6as specified
227AccessoryCasters5-inch diameter caster set, line-up locks.1setKEC furnish + install11 40 01 K50.7as specified
228Electrical connectionCOLD FOOD COUNTER120 V 1 ph, 7.5 A, 1/3 HP; cord and plug, NEMA 5-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
229Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)1connKEC furnish + installAK-101 schedule I.W. "FS"counted
K51 WALK-IN COOLER W.A. Brown 18 lines
#GroupItemDetailQtyUnitBySourceBasis
230FabricationWALK-IN COOLERW.A. Brown1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K51counted
231Walk-inInsulated wall and ceiling panels4 in foamed-in-place polyurethane, 2.5 lb, 24 ga embossed galvanized both faces exposed, cam-lock; area from the plan (field verify)1lotKEC furnish + install11 40 01 K51 & K52assumed
232Walk-inVinyl wall tracksecures cooler walls to the quarry tile floor by others (no cooler floor)1lotKEC furnish + install11 40 01 K51 & K52as specified
233Walk-inDoor, 34 x 78 inthree lift-type hinges, 30 in 16 ga stainless kick plates both sides, sill wiper, padlocking pull handle with inside safety release, automatic closer1eaKEC furnish + install11 40 01 K51 & K52as specified
234Walk-inStrip curtaintransparent vinyl, overlapping strips, aluminum hanging rod and brackets1eaKEC furnish + install11 40 01 K51 & K52as specified
235Walk-inDiamond tread wainscot1/8 in, exposed front exterior, floor to 48 in AFF1lotKEC furnish + install11 40 01 K51 & K52assumed
236Walk-inClosure panels and top closuretrim to building surfaces; top closure with C-channel rails, lift-out sections 48 in max1lotKEC furnish + install11 40 01 K51 & K52as specified
237Walk-inUtility sleeves and escutcheonsfoam-filled after lines are installed, stainless escutcheons1lotKEC furnish + install11 40 01 K51 & K52as specified
238Walk-inThreshold / rampfor carts into the compartment1eaKEC furnish + install11 40 01 K51 & K52as specified
239Walk-inVapor-proof light fixturesprewired to a switch with pilot light in the door section; add fixtures to reach 30 fc at 30 in1lotKEC furnish + install11 40 01 K51 & K52assumed
240Walk-inDigital thermometerowner furnished, KEC installs1eaKEC furnish + install11 40 01 K51 & K52as specified
241Walk-inCondensing unit, medium temp1 HP air-cooled remote, roof mounted, painted galvanized housing, crankcase heater, prewired disconnect; roof curb coordinated1eaKEC furnish + install11 40 01 K51 & K52as specified
242Walk-inUnit cooler (evaporator), low silhouetteat the locations shown1eaKEC furnish + install11 40 01 K51 & K52as specified
243Walk-inRefrigeration piping and specialtiessuction and liquid lines with insulation, sight glass, vibration eliminator, filter-drier, suction filter, TXV, solenoid, thermostat, pump-down circuit; conduit between coil and condensing unit; route length is field verified (roof)1systemKEC furnish + install11 40 01 K51 & K52assumed
244Walk-inEvaporator drain lineto a floor receptor outside the box1eaKEC furnish + install11 40 01 K51 & K52as specified
245Electrical connectionCONDENSING UNIT208 V 3 ph, 9.5 A, 1 HP; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
246Electrical connectionLIGHTS & DOOR HEATER120 V 1 ph, 2.8 A; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
247Electrical connectionEVAPORATOR COIL120 V 1 ph, 3.6 A; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
K52 WALK-IN FREEZER W.A. Brown 19 lines
#GroupItemDetailQtyUnitBySourceBasis
248FabricationWALK-IN FREEZERW.A. Brown1eaKEC furnish + installAK-101 plan (1 tag); 11 40 01 K52counted
249Walk-inInsulated wall and ceiling panels4 in foamed-in-place polyurethane, 2.5 lb, 24 ga embossed galvanized both faces exposed, cam-lock; area from the plan (field verify)1lotKEC furnish + install11 40 01 K51 & K52assumed
250Walk-inInsulated floor panels850 psf, one-piece where possible, staggered joints; 0.10 in diamond tread aluminum finish1lotKEC furnish + install11 40 01 K51 & K52as specified
251Walk-inDoor, 34 x 78 inthree lift-type hinges, 30 in 16 ga stainless kick plates both sides, sill wiper, padlocking pull handle with inside safety release, automatic closer1eaKEC furnish + install11 40 01 K51 & K52as specified
252Walk-inHeated door frameperimeter heat at the freezer door1eaKEC furnish + install11 40 01 K51 & K52as specified
253Walk-inStrip curtaintransparent vinyl, overlapping strips, aluminum hanging rod and brackets1eaKEC furnish + install11 40 01 K51 & K52as specified
254Walk-inDiamond tread wainscot1/8 in, exposed front exterior, floor to 48 in AFF1lotKEC furnish + install11 40 01 K51 & K52assumed
255Walk-inClosure panels and top closuretrim to building surfaces; top closure with C-channel rails, lift-out sections 48 in max1lotKEC furnish + install11 40 01 K51 & K52as specified
256Walk-inUtility sleeves and escutcheonsfoam-filled after lines are installed, stainless escutcheons1lotKEC furnish + install11 40 01 K51 & K52as specified
257Walk-inThreshold / rampfor carts into the compartment1eaKEC furnish + install11 40 01 K51 & K52as specified
258Walk-inVapor-proof light fixturesprewired to a switch with pilot light in the door section; add fixtures to reach 30 fc at 30 in1lotKEC furnish + install11 40 01 K51 & K52assumed
259Walk-inDigital thermometerowner furnished, KEC installs1eaKEC furnish + install11 40 01 K51 & K52as specified
260Walk-inCondensing unit, low temp3 HP air-cooled remote, roof mounted, painted galvanized housing, crankcase heater, prewired disconnect; roof curb coordinated1eaKEC furnish + install11 40 01 K51 & K52as specified
261Walk-inUnit cooler (evaporator), low silhouettetimed electric defrost; at the locations shown1eaKEC furnish + install11 40 01 K51 & K52as specified
262Walk-inRefrigeration piping and specialtiessuction and liquid lines with insulation, sight glass, vibration eliminator, filter-drier, suction filter, TXV, solenoid, thermostat, pump-down circuit; conduit between coil and condensing unit; route length is field verified (roof)1systemKEC furnish + install11 40 01 K51 & K52assumed
263Walk-inEvaporator drain lineto a floor receptor outside the box; heater cable and premolded insulation1eaKEC furnish + install11 40 01 K51 & K52as specified
264Electrical connectionCONDENSING UNIT208 V 3 ph, 16.9 A, 3 HP; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
265Electrical connectionLIGHTS & DOOR HEATER120 V 1 ph, 2.8 A; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
266Electrical connectionEVAPORATOR COIL208 V 1 ph, 16.0 A; direct connection, disconnect and final connection by Div 261connBy othersAK-101 schedule electricalcounted
K60 REACH-IN REFRIGERATOR Traulsen G20010; (1) REQ'D, SEE SHEET A-752A FOR LOCATION 4 lines
#GroupItemDetailQtyUnitBySourceBasis
267EquipmentREACH-IN REFRIGERATORTraulsen G20010; (1) REQ'D, SEE SHEET A-752A FOR LOCATION1eaKEC furnish + installAK-101 schedule "(1) REQ'D"; 11 40 00 K60as specified
268CoordinationApproved alternatesDelfield; Traulsen; True Food Service Equipment, IncKEC furnish + installK60 spec Bas specified
269AccessoryCastersHeavy duty casters, lockable.1setKEC furnish + install11 40 00 K60.12as specified
270Electrical connectionREACH-IN REFRIGERATOR120 V 1 ph, 7.4 A, 3.5 kW, 1/3 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
K61 REACH-IN FREEZER Traulsen G22010; (1) REQ'D, SEE SHEET A-752A FOR LOCATION 4 lines
#GroupItemDetailQtyUnitBySourceBasis
271EquipmentREACH-IN FREEZERTraulsen G22010; (1) REQ'D, SEE SHEET A-752A FOR LOCATION1eaKEC furnish + installAK-101 schedule "(1) REQ'D"; 11 40 00 K61as specified
272CoordinationApproved alternatesDelfield; Traulsen; True Food Service Equipment, IncKEC furnish + installK61 spec Bas specified
273AccessoryCastersHeavy duty casters, lockable.1setKEC furnish + install11 40 00 K61.12as specified
274Electrical connectionREACH-IN FREEZER120 V 1 ph, 11.2 A, 9.9 kW, 1/3 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)1connBy othersAK-101 schedule electricalcounted
K62 ICE MACHINE Manitowoc NEO 240; (3) REQ'D, PROVIDE WATER FILTER SYSTEM 8 lines
#GroupItemDetailQtyUnitBySourceBasis
275EquipmentICE MACHINEManitowoc NEO 240; (3) REQ'D, PROVIDE WATER FILTER SYSTEM3eaKEC furnish + installAK-101 schedule "(3) REQ'D"; 11 40 00 K62as specified
276CoordinationApproved alternatesHoshizaki; Manitowoc; Approved EqualKEC furnish + installK62 spec Bas specified
277AccessoryIce scoop and holderProvide scoop, internal scoop holder3eaKEC furnish + install11 40 00 K62.10as specified
278Plumbing connectionFlexible water supply hose3/8"3eaKEC furnish + install11 40 00 K62.12as specified
279AccessoryWater filtration systemsingle cartridge water filtration system recommended by manufacturer for use with the ice machine, rated NSF Class1, STD 42.3eaKEC furnish + install11 40 00 K62.13as specified
280Electrical connectionICE MACHINE & BIN120 V 1 ph, 7.0 A, 1/3 HP, at 44" AFF; cord and plug, NEMA 5-15P (receptacle by Div 26)3connBy othersAK-101 schedule electricalcounted
281Plumbing connectionCold water 3/8"rough-in and final connection by Div 22; KEC furnishes the faucet, valve or fitting the item calls for3connBy othersAK-101 schedule plumbingcounted
282Plumbing connectionIndirect waste to floor sinkKEC extends the equipment drain to the receptor with an air gap (IPC 802, 2x the pipe diameter, 1 in min); the receptor is by plumbing (plan note)3connKEC furnish + installAK-101 schedule I.W. "FS"counted
P1 HAND SINK SEE PLUMBING DRAWINGS 1 lines
#GroupItemDetailQtyUnitBySourceBasis
283By othersHAND SINKSEE PLUMBING DRAWINGS2eaBy others (in contract)AK-101 schedule, "Equipment by others, in contract"counted
M1 GREASE EXHAUST HOOD SEE MECHANICAL DRAWINGS 1 lines
#GroupItemDetailQtyUnitBySourceBasis
284By othersGREASE EXHAUST HOODSEE MECHANICAL DRAWINGS1eaBy others (in contract)AK-101 schedule, "Equipment by others, in contract"counted
M2 GREASE EXHAUST HOOD SEE MECHANICAL DRAWINGS 1 lines
#GroupItemDetailQtyUnitBySourceBasis
285By othersGREASE EXHAUST HOODSEE MECHANICAL DRAWINGS1eaBy others (in contract)AK-101 schedule, "Equipment by others, in contract"counted
M3 FLY FAN SEE MECHANICAL DRAWINGS 1 lines
#GroupItemDetailQtyUnitBySourceBasis
286By othersFLY FANSEE MECHANICAL DRAWINGS1eaBy others (in contract)AK-101 schedule, "Equipment by others, in contract"counted
E1 UTILITY DISTRIBUTION SYSTEM SEE MECHANICAL DRAWINGS 1 lines
#GroupItemDetailQtyUnitBySourceBasis
287By othersUTILITY DISTRIBUTION SYSTEMSEE MECHANICAL DRAWINGS1eaBy others (in contract)AK-101 schedule, "Equipment by others, in contract"counted